Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability

Christian Booz, Giuseppe M Bucolo, Tommaso D'Angelo, Silvio Mazziotti, Ludovica R M Lanzafame, Ibrahim Yel, Leona S Alizadeh, Leon D Gruenewald, Vitali Koch, Simon S Martin, Mirela Dimitrova, Aynur Goekduman und 4 weitere

La radiologia medica · 2024

DOI: 10.1007/s11547-024-01889-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift La radiologia medica, 2024. Verfasst von Christian Booz und 15 weiteren Autor:innen. Beteiligte Einrichtung: Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, F…. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio, Contrast Media, Computed Tomography Angiography, Carotid Arteries. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Preliminary dual-energy CT studies have shown that low-energy virtual monoenergetic (VMI) + reconstructions can provide superior image quality compared to standard 120 kV CTA series. The purpose of this study is to evaluate the impact of low-energy VMI reconstructions on quantitative and qualitative image quality, vascular contrast, and diagnostic assessability of the carotid artery in patients undergoing photon-counting CTA examinations. Materials and methods A total of 122 patients (67 male) who had undergone dual-source photon-counting CTA scans of the carotid artery were retrospectively analyzed in this study. Standard 120 kV CT images and low-keV VMI series from 40 to 100 keV with an interval of 15 keV were reconstructed. Quantitative analyses included the evaluation of vascular CT numbers, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). CT number measurements were performed in the common, external, and internal carotid arteries. Qualitative analyses were performed by three board-certified radiologists independently using five-point scales to evaluate image quality, vascular contrast, and diagnostic assessability of the carotid artery.

Results

Mean attenuation, CNR and SNR values were highest in 40 keV VMI reconstructions (HU, 1362.32 ± 457.81; CNR, 33.19 ± 12.86; SNR, 34.37 ± 12.89) followed by 55-keV VMI reconstructions (HU, 736.94 ± 150.09; CNR, 24.49 ± 7.11; SNR, 26.25 ± 7.34); all three mean values at these keV levels were significantly higher compared with the remaining VMI series and standard 120 kV CT series (HU, 154.43 ± 23.69; CNR, 16.34 ± 5.47; SNR, 24.44 ± 7.14) ( p < 0.0001). The qualitative analysis showed the highest rating scores for 55 keV VMI reconstructions followed by 40 keV and 70 keV VMI series with a significant difference compared to standard 120 kV CT images series regarding image quality, vascular contrast, and diagnostic assessability of the carotid artery (all comparisons, p < 0.01).

Conclusions

Low-keV VMI reconstructions at a level of 40–55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal-To-Noise RatioContrast MediaComputed Tomography AngiographyCarotid ArteriesHumansMaleFemaleRetrospective StudiesMiddle AgedAgedAged, 80 and overAdultRadiographic Image Interpretation, Computer-AssistedRadiography, Dual-Energy Scanned ProjectionTomography, X-Ray Computed

Stichwörter der Autor:innen

Carotid arteriesDual-energy CTPhoton-counting CTVirtual monoenergetic imaging

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany.
  • Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany.
  • Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy.
  • Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy. tommasodang@gmail.com.
  • Department of Radiology and Nuclear Medicine, Erasmus MC, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands. tommasodang@gmail.com.
  • Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072, Koblenz, Germany.

Zitieren

APA

Booz, C., Bucolo, G. M., D'Angelo, T., Mazziotti, S., Lanzafame, L. R. M., Yel, I., Alizadeh, L. S., Gruenewald, L. D., Koch, V., Martin, S. S., Dimitrova, M., Goekduman, A., Vogl, T. J., Kaatsch, H. L., Overhoff, D., & Waldeck, S. (2024). Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability. La radiologia medica. https://doi.org/10.1007/s11547-024-01889-6

Vancouver

Booz C, Bucolo GM, D'Angelo T, Mazziotti S, Lanzafame LRM, Yel I, et al. Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability. La radiologia medica. 2024. doi:10.1007/s11547-024-01889-6

BibTeX
@article{Booz2024,
  author = {Booz, Christian and Bucolo, Giuseppe M and D'Angelo, Tommaso and Mazziotti, Silvio and Lanzafame, Ludovica R M and Yel, Ibrahim and Alizadeh, Leona S and Gruenewald, Leon D and Koch, Vitali and Martin, Simon S and Dimitrova, Mirela and Goekduman, Aynur and Vogl, Thomas J and Kaatsch, Hanns L and Overhoff, Daniel and Waldeck, Stephan},
  title = {Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability},
  journal = {La radiologia medica},
  year = {2024},
  doi = {10.1007/s11547-024-01889-6}
}
Kostenlos starten →