The optimal energy level of virtual monochromatic imaging in dual-energy CT arthrography of the wrist
British Journal of Radiology · 01.02.2025 · 98 (1166) · 305-311
DOI: 10.1093/bjr/tqae238 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Radiology, online erschienen am 14.11.2024. Verfasst von Bo Mi Chung und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, 06973, Republic of Korea. Hauptthemen laut MEDLINE: Arthrography, Tomography, X-Ray Computed, Wrist Joint, Radiography, Dual-Energy Scanned Projection. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben. Gefördert von: Chung-Ang University Research.
Abstract (Originalsprache)
Objectives
To suggest an optimal energy level of virtual monochromatic images (VMIs) in dual-energy CT (DECT) arthrography of the wrist.
Methods
This retrospective study included 53 patients with wrist CT arthrography. Conventional polychromatic images and VMIs at 4 energy levels (40–70 keV at 10 keV intervals) were obtained. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured, and qualitative analysis of image quality and diagnostic confidence was performed. For each patient, an energy level with the best image quality was chosen by consensus. Comparisons of quantitative and qualitative parameters between VMI sets were performed.
Results
The image noise of bone and muscle were increased with decreasing energy level (P < .001). The noise of contrast was highest on 60 keV VMI. SNR and CNR (between contrast and muscle) were increased with decreasing energy level and were markedly increased between 60 and 50 keV (P < .001). The 60 keV VMI demonstrated the highest image quality and diagnostic confidence, chosen as the best diagnostic image (n = 31/53). Given that the attenuation of the contrast material was low on the conventional image, the optimal energy level of the best VMI tended to be low.
Conclusions
Wrist DECT arthrography with VMIs at 60 keV or less could improve image quality and diagnostic performance by increasing SNR and CNR in cases with low contrast attenuation. Advances in knowledge Wrist DECT arthrography with VMIs at variable keV could be utilized to enhance SNR and CNR, thereby achieving diagnostic images of high quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, 06973, Republic of Korea.
- Department of Radiology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Gyeonggi-do, 14353, Republic of Korea.
ORCID-Profile: Sujin Kim
Förderung
- Chung-Ang University Research
Zitieren
APA
Chung, B. M., Lee, G. Y., & Kim, S. (2025). The optimal energy level of virtual monochromatic imaging in dual-energy CT arthrography of the wrist. British Journal of Radiology, 98(1166), 305-311. https://doi.org/10.1093/bjr/tqae238
Vancouver
Chung BM, Lee GY, Kim S. The optimal energy level of virtual monochromatic imaging in dual-energy CT arthrography of the wrist. British Journal of Radiology. 2025;98(1166):305-311. doi:10.1093/bjr/tqae238
BibTeX
@article{Chung2025,
author = {Chung, Bo Mi and Lee, Guen Young and Kim, Sujin},
title = {The optimal energy level of virtual monochromatic imaging in dual-energy CT arthrography of the wrist},
journal = {British Journal of Radiology},
year = {2025},
volume = {98},
number = {1166},
pages = {305--311},
doi = {10.1093/bjr/tqae238}
}