EANM position paper on challenges and opportunities of full-ring 360° CZT bone imaging: it’s time to let go of planar whole-body bone imaging
European Journal of Nuclear Medicine and Molecular Imaging · 2025
DOI: 10.1007/s00259-024-06906-4 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2025. Verfasst von Richard Graham und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Royal United Hopital, Bath, UK. Hauptthemen laut MEDLINE: Whole Body Imaging, Bone and Bones, Tellurium, Zinc. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsmedizin Rostock.
Abstract (Originalsprache)
The introduction of smaller footprint, more sensitive Cadmium-Zinc-Telluride (CZT)-based detectors with improved spatial and energy resolution has enabled the design of innovative full-ring 360° CZT SPECT/CT systems (e.g., VERITON ® and StarGuide™). With this transformative technology now aiming to become mainstream in clinical practice, several critical questions need to be addressed. This EANM position paper provides practical recommendations on how to use these devices for routine bone SPECT/CT studies, facilitating the transition from traditional planar whole-body imaging and conventional SPECT/CT to these novel systems. In particular, initial guidance is provided on imaging acquisition and reporting workflows, image reconstruction, and CT acquisition parameters. Given the emerging nature of this technology, the available evidence base is still limited, and the proposed adaptations in workflows and scan protocols will likely evolve before being integrated into definitive guidelines. In the meantime, this EANM position paper serves as a comprehensive guide for integrating these advanced hybrid SPECT/CT imaging systems into clinical practice and outlining areas for further study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Royal United Hopital, Bath, UK.
- Department of Nuclear Medicine, Institut Jean-Godinot, Reims, France.
- Department of Medical Physics, Royal United Hopital, Bath, UK.
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU Nancy, Université de Lorraine, IADI, INSERM U1254, Nancy, France.
- PET/CT Oncology Center 'Theageneio', Thessaloniki, Greece.
- Department of Nuclear Medicine, Rostock University Medical Center, Rostock, Germany. jens.kurth@med.uni-rostock.de.
ORCID-Profile: Jens Kurth
Förderung
- Universitätsmedizin Rostock
Zitieren
APA
Graham, R., Morland, D., Cade, S., Imbert, L., Panagiotidis, E., Kurth, J., Paycha, F., & Van den Wyngaert, T. (2025). EANM position paper on challenges and opportunities of full-ring 360° CZT bone imaging: it’s time to let go of planar whole-body bone imaging. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-024-06906-4
Vancouver
Graham R, Morland D, Cade S, Imbert L, Panagiotidis E, Kurth J, et al. EANM position paper on challenges and opportunities of full-ring 360° CZT bone imaging: it’s time to let go of planar whole-body bone imaging. European Journal of Nuclear Medicine and Molecular Imaging. 2025. doi:10.1007/s00259-024-06906-4
BibTeX
@article{Graham2025,
author = {Graham, Richard and Morland, David and Cade, Sarah and Imbert, Laetitia and Panagiotidis, Emmanouil and Kurth, Jens and Paycha, Frédéric and Van den Wyngaert, Tim},
title = {EANM position paper on challenges and opportunities of full-ring 360° CZT bone imaging: it’s time to let go of planar whole-body bone imaging},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2025},
doi = {10.1007/s00259-024-06906-4}
}
EUVIMED