EUVIMEDEUVIMED entdecken
Crossref

Standardized uptake value-based analysis of two-phase whole-body bone tomoscintigraphies recorded with a high-speed 360° CZT camera in patients with known or suspected inflammatory arthritis

Franklin Rajadhas, Laetitia Imbert, Mathilde Fiorino, Caroline Morizot, Victor Boucher, Zohra Lamiral, Véronique Roch, Pierre-Yves Marie, Damien Loeuille, Isabelle Chary-Valckenaere, Achraf Bahloul iD

European Journal of Nuclear Medicine and Molecular Imaging · 2025

DOI: 10.1007/s00259-025-07150-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2025. Verfasst von Franklin Rajadhas und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Vandoeuvre-Les-Nancy, 54000, France. Hauptthemen laut MEDLINE: Single Photon Emission Computed Tomography Computed Tomography, Whole Body Imaging, Arthritis, Tellurium. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: 360° CZT-cameras provide whole-body bone SPECT/CT recordings at delayed (DEL) and blood-pool (BP) phases with short recording times but long visual analysis times. This study aims to determine whether a standardized uptake value (SUV)-based detection of inflammatory arthritis (IA) could facilitate this analysis. METHODS: We included 72 patients with known or suspected IA who underwent two-phase whole-body bone SPECT/CT after 550-650 MBq [99mTc]Tc-HDP injection. Forty-eight patients also had ultrasound (US) for peripheral IA, and 42 had MRI for axial IA. The skeleton was segmented into 26 joint areas and analyzed by trained observers using a visual consensus methodology and SUVmax measurements. RESULTS: A total of 1836 joint areas were analyzed, including 1126 peripheral ones (limb joints excluding hips and shoulders). SUVmax was predictive of visually abnormal SPECT joints with high areas under receiver-operating-characteristic (ROC) curves for non-peripheral (BP-SPECT: 0.941 ± 0.017, DEL-SPECT: 0.910 ± 0.014) and especially peripheral (BP-SPECT: 0.980 ± 0.005, DEL-SPECT: 0.939 ± 0.012) joints. An SUVmax threshold-based prediction of visual SPECT abnormalities had high negative predictive values (BP-SPECT: 99.2% (1479/1491), DEL-SPECT: 97.2% (1333/1372)) but low positive predictive values (BP-SPECT: 35.1% (121/345), DEL-SPECT: 51.2% (237/463)). MRI- and US-defined IA were best predicted by a visually abnormal BP-SPECT due to higher specificities than SUVmax thresholds (all p < 0.05). CONCLUSION: On two-phase whole-body bone SPECT/CT, an SUVmax-based IA detection may not replace the conventional visual method. However, given the high negative predictive values provided by SUVmax thresholds, the time-consuming visual analysis of SPECT/CT slices could be confined to the small proportion of joints exceeding these thresholds.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Single Photon Emission Computed Tomography Computed TomographyWhole Body ImagingArthritisTelluriumBone and BonesHumansMaleFemaleMiddle AgedAgedAdultAged, 80 and overReference StandardsBiological TransportCadmiumZinc

Stichwörter der Autor:innen

BoneQuantitativeSPECTSUVWhole body

Substanzen

TelluriumCdZnTeCadmiumZinc

Autor:innen und Institutionen

  • Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Vandoeuvre-Les-Nancy, 54000, France.
  • Université de Lorraine, INSERM U1254, IADI, Nancy, 54000, France.
  • Department of Rheumatology, CHRU Nancy, Vandoeuvre-Les-Nancy, 54500, France.
  • UMR 7365 CNRS- ImoPA Nancy University Hospital and University of Lorraine, Vandoeuvre-Les-Nancy, 54500, France.
  • Université de Lorraine, CHRU-Nancy, INSERM, CIC 1433, Nancy, 54000, France.
  • Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU-Nancy, Vandoeuvre-Les-Nancy, 54000, France. a.bahloul@chru-nancy.fr.

ORCID-Profile: Achraf Bahloul

Zitieren

APA

Rajadhas, F., Imbert, L., Fiorino, M., Morizot, C., Boucher, V., Lamiral, Z., Roch, V., Marie, P. Y., Loeuille, D., Chary-Valckenaere, I., & Bahloul, A. (2025). Standardized uptake value-based analysis of two-phase whole-body bone tomoscintigraphies recorded with a high-speed 360° CZT camera in patients with known or suspected inflammatory arthritis. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-025-07150-0

Vancouver

Rajadhas F, Imbert L, Fiorino M, Morizot C, Boucher V, Lamiral Z, et al. Standardized uptake value-based analysis of two-phase whole-body bone tomoscintigraphies recorded with a high-speed 360° CZT camera in patients with known or suspected inflammatory arthritis. European Journal of Nuclear Medicine and Molecular Imaging. 2025. doi:10.1007/s00259-025-07150-0

BibTeX
@article{Rajadhas2025,
  author = {Rajadhas, Franklin and Imbert, Laetitia and Fiorino, Mathilde and Morizot, Caroline and Boucher, Victor and Lamiral, Zohra and Roch, Véronique and Marie, Pierre-Yves and Loeuille, Damien and Chary-Valckenaere, Isabelle and Bahloul, Achraf},
  title = {Standardized uptake value-based analysis of two-phase whole-body bone tomoscintigraphies recorded with a high-speed 360° CZT camera in patients with known or suspected inflammatory arthritis},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2025},
  doi = {10.1007/s00259-025-07150-0}
}
Kostenlos starten →