Platform-specific impact of CT attenuation correction on CZT myocardial perfusion SPECT: per-vessel detection of obstructive coronary artery disease
The International Journal of Cardiovascular Imaging · 12.08.2026 · 42 (11) · 2217-2231
DOI: 10.1007/s10554-026-03791-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, online erschienen am 12.08.2026. Verfasst von Yoshimitsu Honda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Nippon Medical School, Tokyo, Japan. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Coronary Artery Disease, Coronary Angiography, Coronary Stenosis. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Attenuation artifacts on myocardial perfusion SPECT differ across camera geometries. This study evaluated whether CT attenuation correction (CTAC) improves per-vessel detection of obstructive coronary artery disease (CAD) on a stationary 19-pinhole CZT system. Rest-stress ⁹⁹ᵐTc-tetrofosmin CZT SPECT studies from 48 patients with angiographically confirmed CAD (185 vessels) were retrospectively reconstructed with and without CTAC. The reference standard was ≥ 70% diameter stenosis on coronary CT angiography or invasive angiography, with no perfusion input. Disease-negative participants were excluded by design. Perfusion was quantified as the percent defect averaged within each coronary territory, assigned per patient on hybrid SPECT/CT fusion images. Per-vessel discrimination of the reversible (stress - rest) defect rate was compared between reconstructions. Compared with non-attenuation-corrected (NAC) reconstructions, CTAC lowered the global rest defect rate (P < 0.0001) and raised the reversible defect rate (median 5.9% vs. 1.5%; P < 0.0001). The reversible defect rate discriminated territories subtended by obstructive stenosis better with CTAC than with NAC (AUC 0.717 vs. 0.614; ΔAUC 0.103; DeLong P = 0.0164; bootstrap P = 0.010; within-patient permutation P = 0.0474). At the Youden point, sensitivity rose to 75.5% from 52.8%, with specificity 64.4% versus 68.9%. The gain was greatest in the LCX (0.803 vs. 0.658; P = 0.043) and RCA territories. On this 19-pinhole CZT platform, CTAC improves per-vessel discrimination of obstructive CAD, most prominently in the LCX and RCA territories. The benefit is sensitivity-led, opposite to the specificity-led gain reported on Anger cameras, at a modest cost in specificity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Nippon Medical School, Tokyo, Japan.
- Department of Radiology, Nippon Medical School, Tokyo, Japan. fuku@nms.ac.jp.
- Department of Cardiovascular Medicine, Nippon Medical School, Tokyo, Japan.
Zitieren
APA
Honda, Y., Fukushima, Y., Yodogawa, K., Nakaoka, Y., Hayashi, H., & Kumita, S. (2026). Platform-specific impact of CT attenuation correction on CZT myocardial perfusion SPECT: per-vessel detection of obstructive coronary artery disease. The International Journal of Cardiovascular Imaging, 42(11), 2217-2231. https://doi.org/10.1007/s10554-026-03791-w
Vancouver
Honda Y, Fukushima Y, Yodogawa K, Nakaoka Y, Hayashi H, Kumita S. Platform-specific impact of CT attenuation correction on CZT myocardial perfusion SPECT: per-vessel detection of obstructive coronary artery disease. The International Journal of Cardiovascular Imaging. 2026;42(11):2217-2231. doi:10.1007/s10554-026-03791-w
BibTeX
@article{Honda2026,
author = {Honda, Yoshimitsu and Fukushima, Yoshimitsu and Yodogawa, Kenji and Nakaoka, Yujiro and Hayashi, Hiromitsu and Kumita, Shinichiro},
title = {Platform-specific impact of CT attenuation correction on CZT myocardial perfusion SPECT: per-vessel detection of obstructive coronary artery disease},
journal = {The International Journal of Cardiovascular Imaging},
year = {2026},
volume = {42},
number = {11},
pages = {2217--2231},
doi = {10.1007/s10554-026-03791-w}
}
EUVIMED