EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Acetabular cup anteversion measurement in total hip arthroplasty: reliability of metal artifact reduction MRI compared with CT

Frederik Abel, Patrick O Zingg, Reto Sutter, Florian Schmaranzer

Skeletal Radiology · 2026-06 · 55 (6) · 1329-1336

DOI: 10.1007/s00256-026-05161-y ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Skeletal Radiology, online erschienen am 12.02.2026. Verfasst von Frederik Abel und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland. freder…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Magnetic Resonance Imaging, Tomography, X-Ray Computed, Acetabulum. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The acetabular cup version in patients with total hip arthroplasty (THA) is a key parameter influencing hip stability and functional outcomes. Although CT remains the reference standard for assessing cup orientation, MRI with metal artifact reduction techniques is increasingly used for evaluating postoperative pain. This study compared MRI- and CT-based measurements of acetabular cup version regarding agreement, reproducibility, and reliability. Material and methods Patients who underwent THA between 2015 and 2025 with postoperative CT and MRI were retrospectively analyzed. MRI was performed using optimized metal artifact reduction sequences. Acetabular cup version was measured on axial high-bandwidth T1-weighted turbo spin-echo sequences and on corresponding CT scans by two musculoskeletal radiologists. Inter- and intra-reader, as well as inter-modality agreement, were assessed using intraclass correlation coefficients (ICC). Bland-Altman plots evaluated systematic bias.

Results

Thirty patients were included (mean age, 64.1 years; 14 women). Mean acetabular version was 31.2° (standard deviation (SD), 9.4–10.3) for CT and 30.1–30.2° (SD, 8.9–9.3) for MRI for both readers. Inter-reader agreement was almost perfect for CT (ICC, 0.96) and substantial for MRI (ICC, 0.76). Intra-reader agreement was almost perfect for both modalities (ICC, CT, 0.99; MRI, 0.94). Bland-Altman analysis showed no statistically significant differences between CT and MRI measurements with a slight positive bias for MRI (mean pooled difference, 1.1°; p = 0.058; limits of agreement, −4.7 to 6.8°) and almost perfect agreement for both readers (ICC, 0.86–0.90).

Conclusion

MRI measures acetabular cup version with excellent reliability and close agreement with CT, reinforcing MRI’s role in postoperative THA evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipMagnetic Resonance ImagingTomography, X-Ray ComputedAcetabulumHip ProsthesisHumansArtifactsReproducibility of ResultsFemaleRetrospective StudiesMiddle AgedMetalsMaleAged

Stichwörter der Autor:innen

Acetabular anteversion measurementComputed tomographyMagnetic resonance imagingMetal artifact reduction sequencesProsthetic hip imagingTotal hip arthroplasty

Substanzen

Metals

Autor:innen und Institutionen

  • Department of Radiology, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland. frederik.abel@balgrist.ch.
  • Department of Orthopedic Surgery, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
  • Department of Radiology, Faculty of Medicine, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
  • Department of Diagnostic, Interventional- and Paediatric Radiology, Inselspital, University of Bern, Rosenbühlgasse 27, 3010, Bern, Switzerland.

Zitieren

APA

Abel, F., Zingg, P. O., Sutter, R., & Schmaranzer, F. (2026). Acetabular cup anteversion measurement in total hip arthroplasty: reliability of metal artifact reduction MRI compared with CT. Skeletal Radiology, 55(6), 1329-1336. https://doi.org/10.1007/s00256-026-05161-y

Vancouver

Abel F, Zingg PO, Sutter R, Schmaranzer F. Acetabular cup anteversion measurement in total hip arthroplasty: reliability of metal artifact reduction MRI compared with CT. Skeletal Radiology. 2026;55(6):1329-1336. doi:10.1007/s00256-026-05161-y

BibTeX
@article{Abel2026,
  author = {Abel, Frederik and Zingg, Patrick O and Sutter, Reto and Schmaranzer, Florian},
  title = {Acetabular cup anteversion measurement in total hip arthroplasty: reliability of metal artifact reduction MRI compared with CT},
  journal = {Skeletal Radiology},
  year = {2026},
  volume = {55},
  number = {6},
  pages = {1329--1336},
  doi = {10.1007/s00256-026-05161-y}
}
Kostenlos starten →