Photon-counting CT yields superior abdominopelvic image quality at lower radiation and iodinated contrast doses
Pediatric Radiology · 2025
DOI: 10.1007/s00247-025-06209-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, 2025. Verfasst von Fides Regina Schwartz und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA. frschwartz@bwh.harvard.edu. Hauptthemen laut MEDLINE: Radiation Dosage, Contrast Media, Tomography, X-Ray Computed, Radiography, Abdominal. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 45 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Photon-counting detector (PCD) computed tomography (CT) has been shown to provide better image quality at lower radiation and intravenous contrast doses than energy-integrating detector (EID) CT in adult patients. There is limited data on these benefits for the pediatric population especially for abdominopelvic CT examinations. OBJECTIVE: This study examines a reduced weight-based iodinated contrast dosing strategy in pediatric abdominopelvic CT on a PCD-CT system compared to standard dosing protocols on EID-CT using 1 mL/kg and 2 mL/kg, respectively. Image quality is assessed using both quantitative and qualitative measures. We also compare the radiation dose profile between the two PCD-CT and EID-CT cohorts. MATERIALS AND METHODS: This HIPAA-compliant, IRB-approved, retrospective study included pediatric patients (≤18 years of age) who underwent contrast-enhanced CT examinations of the abdomen and pelvis for routine clinical care (01/2022 - 01/2023) in the portal-venous phase on a PCD-CT (NAEOTOM Alpha; Siemens Healthineers). Inclusion criteria included a similar prior examination within 12-months on a dual-source EID-CT scanner from the same vendor. All PCD-CT and EID-CT scans were acquired using weight-based dosing for intravenous contrast media, 1 mL/kg and 2 mL/kg, respectively, based on institutional protocols. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured in the aorta, portal vein, liver parenchyma, and skeletal muscle. Three pediatric radiologists qualitatively evaluated each scan for overall image quality, noise, and contrast on a scale of 0-100. Confidence in small structure detection (common bile duct) was also rated on a scale of 0-3. Radiation doses (size-specific dose estimate (SSDE)) were calculated. Statistical analysis included paired t-tests and a mixed linear effects model to account for patient age, sex, and X-ray tube voltage. A P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA. frschwartz@bwh.harvard.edu.
- Duke University Health System, Durham, USA.
Zitieren
APA
Schwartz, F. R., Bache, S., Lee, R., Maxfield, C. M., Fadell, M. F., Gaca, A. M., Samei, E., Frush, D. P., & Cao, J. Y. (2025). Photon-counting CT yields superior abdominopelvic image quality at lower radiation and iodinated contrast doses. Pediatric Radiology. https://doi.org/10.1007/s00247-025-06209-2
Vancouver
Schwartz FR, Bache S, Lee R, Maxfield CM, Fadell MF, Gaca AM, et al. Photon-counting CT yields superior abdominopelvic image quality at lower radiation and iodinated contrast doses. Pediatric Radiology. 2025. doi:10.1007/s00247-025-06209-2
BibTeX
@article{Schwartz2025,
author = {Schwartz, Fides Regina and Bache, Steve and Lee, Rachel and Maxfield, Charles M and Fadell, Michael F and Gaca, Ana M and Samei, Ehsan and Frush, Donald P and Cao, Joseph Y},
title = {Photon-counting CT yields superior abdominopelvic image quality at lower radiation and iodinated contrast doses},
journal = {Pediatric Radiology},
year = {2025},
doi = {10.1007/s00247-025-06209-2}
}
EUVIMED