Comparison of image quality, contrast administration, and radiation doses in pediatric abdominal dual-layer detector dual-energy CT using propensity score matching analysis
European Journal of Radiology · 2023
DOI: 10.1016/j.ejrad.2023.111177 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Radiology, 2023. Verfasst von Yeseul Kang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medici…. Hauptthemen laut MEDLINE: Contrast Media, Radiography, Dual-Energy Scanned Projection. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To compare the image quality, contrast administration, and radiation dose between single-energy CT (SECT) and dual-energy CT (DECT) in pediatric patients. METHODS: From March to December 2021, children who underwent abdominal SECT or DECT were retrospectively included in this study. The DECT group received 10-30 % less contrast than the routine dose. CT images were obtained at hepatic venous phase using a routine reconstruction method (iDose4). DECT scans were additionally reconstructed with a virtual monoenergetic image (VMI) at 40 and 65 keV. Quantitative image evaluations compared the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the liver, portal vein, and pancreas. Qualitative analysis assessed degree of contrast enhancement, lesion or organ conspicuity, image noise, artificiality, and overall image quality. RESULTS: Among 318 patients, 112 (median age, 16 years; 56 in each group) were included after propensity score matching. Compared with the SECT group, DECT group with iDose4 demonstrated lower CNRs and SNRs, while VMI at 40 or 65 keV showed no significant difference. In qualitative analysis, iDose4 produced higher scores on artificiality, and VMI at 40 keV demonstrated superior contrast enhancement and lesion conspicuity in the DECT group. Overall image quality was higher with VMI 65 keV among the DECT patients, and there was no significant difference compared to SECT. The volume CT dose index (CTDIvol) did not differ significantly between the two groups (median, 2.8 mGy vs. 2.9 mGy; p = 0.802). The injected contrast volume was reduced by 10 % in the DECT group. CONCLUSION: Pediatric abdominal DECT with reduced contrast administration showed no significant differences in image quality and radiation dose compared to SECT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Yongin Severance Hospital 363, Dongbaekjukjeon-daero, Giheung-gu,…
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Severance Hospital, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.
Zitieren
APA
Kang, Y., Hwang, S. H., Han, K., & Shin, H. J. (2023). Comparison of image quality, contrast administration, and radiation doses in pediatric abdominal dual-layer detector dual-energy CT using propensity score matching analysis. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2023.111177
Vancouver
Kang Y, Hwang SH, Han K, Shin HJ. Comparison of image quality, contrast administration, and radiation doses in pediatric abdominal dual-layer detector dual-energy CT using propensity score matching analysis. European Journal of Radiology. 2023. doi:10.1016/j.ejrad.2023.111177
BibTeX
@article{Kang2023,
author = {Kang, Yeseul and Hwang, Shin Hye and Han, Kyunghwa and Shin, Hyun Joo},
title = {Comparison of image quality, contrast administration, and radiation doses in pediatric abdominal dual-layer detector dual-energy CT using propensity score matching analysis},
journal = {European Journal of Radiology},
year = {2023},
doi = {10.1016/j.ejrad.2023.111177}
}
EUVIMED