Low dose pediatric chest computed tomography on a photon counting detector system – initial clinical experience
Pediatric Radiology · 13.01.2023 · 53 (6) · 1057-1062
DOI: 10.1007/s00247-022-05584-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, online erschienen am 13.01.2023. Verfasst von Ilias Tsiflikas und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital, Eberhard Karls University Tuebingen, Tuebingen, Germany. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Lung. Die Arbeit wurde bisher 66-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medizinische Fakultät Mannheim der Universität Heidelberg.
Abstract (Originalsprache)
Background
With the clinical release of a photon counting detector-based computed tomography (CT) system, the potential benefits of this new technology need to be evaluated clinically. Literature concerning this new generation of detector is sparse, especially in the field of pediatric radiology. Therefore, this study outlines our initial experience with ultra-low dose chest CT imaging on the new photon counting CT system. Materials and methods A pediatric phantom (1-year old, CIRS ATOM phantom, model 704 [CIRS-computerized imaging reference system, Norfolk, VA]) was scanned at different dose levels and different image quality levels to define a protocol for clinical examinations. Next, 20 consecutive pediatric non-contrast ultra-low dose chest CT examinations were evaluated for radiation dose and diagnostic image quality using a 4-point Likert-scale—1 = excellent, 4 = bad image quality—by two radiologists in a consensus reading. This retrospective analysis was approved by the local research ethics committee.
Results
Chest CT examinations performed at ultra-low radiation dose (effective dose 0.19 ± 0.07 mSv; size-specific dose estimate 0.45 ± 0.14 mGy) in pediatric patients ages (2.6 ± 1.8 years) show good to excellent image quality for lung structures (1.4 ± 0.4) and moderate image quality for soft tissue structures (2.8 ± 0.2).
Conclusion
Pediatric ultra-low dose chest CT examinations are feasible with the new generation photon counting detector-based CT system. The benefits of this technology must be evaluated for pediatric patients from the outset.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, University Hospital, Eberhard Karls University Tuebingen, Tuebingen, Germany.
- Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
- Department of Radiology, Freiburg University Hospital, Freiburg, Germany.
- Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany. meike.weis@medma.uni-heidelb…
ORCID-Profile: Meike Weis
Förderung
- Medizinische Fakultät Mannheim der Universität Heidelberg
Zitieren
APA
Tsiflikas, I., Thater, G., Ayx, I., Weiss, J., Schaefer, J., Stein, T., Schoenberg, S. O., & Weis, M. (2023). Low dose pediatric chest computed tomography on a photon counting detector system – initial clinical experience. Pediatric Radiology, 53(6), 1057-1062. https://doi.org/10.1007/s00247-022-05584-4
Vancouver
Tsiflikas I, Thater G, Ayx I, Weiss J, Schaefer J, Stein T, et al. Low dose pediatric chest computed tomography on a photon counting detector system – initial clinical experience. Pediatric Radiology. 2023;53(6):1057-1062. doi:10.1007/s00247-022-05584-4
BibTeX
@article{Tsiflikas2023,
author = {Tsiflikas, Ilias and Thater, Greta and Ayx, Isabelle and Weiss, Jakob and Schaefer, Juergen and Stein, Thomas and Schoenberg, Stefan O and Weis, Meike},
title = {Low dose pediatric chest computed tomography on a photon counting detector system – initial clinical experience},
journal = {Pediatric Radiology},
year = {2023},
volume = {53},
number = {6},
pages = {1057--1062},
doi = {10.1007/s00247-022-05584-4}
}
EUVIMED