Liquid-phase microextraction of aromatic amines: hollow fiber–liquid-phase microextraction and parallel artificial liquid membrane extraction comparison
Analytical and Bioanalytical Chemistry · 2023
DOI: 10.1007/s00216-023-04579-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2023. Verfasst von Nerea Lorenzo-Parodi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. Hauptthemen laut MEDLINE: Membranes, Artificial, Liquid Phase Microextraction. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Evonik Industries, Universität Duisburg-Essen.
Abstract (Originalsprache)
Aromatic amines (AA) are carcinogenic compounds that can enter the human body through many sources, one of the most important being tobacco smoke. They are excreted with the urine, from which they can be extracted and measured. To that end, hollow fiber-liquid-phase microextraction (HF-LPME) and parallel artificial liquid membrane extraction (PALME) were optimized for the analysis of representative aromatic amines, as alternatives to liquid–liquid extraction (LLE). Relevant extraction parameters, namely organic solvent, extraction time, agitation speed, and acceptor solution pH, were studied, and the two optimized techniques—HF-LPME: dihexyl ether, 45 min, 250 rpm, and pH 1; PALME: undecane, 20 min, 250 rpm and pH 1—were compared. Comparison of the optimized methods showed that significantly higher recoveries could be obtained with PALME than with HF-LPME. Therefore, PALME was further validated. The results were successful for nine different AA, with regression coefficients ( R 2 ) of at least 0.991, limits of detection (LOD) of 45–75 ng/L, and repeatability and peak area relative standard deviations (RSD) below 20%. Furthermore, two urine samples from smokers were measured as proof of concept, and 2-methylaniline was successfully quantified in one of them. These results show that PALME is a great green alternative to LLE. Not only does it use much smaller volumes of toxic organic solvents, and sample—enabling the study of samples with limited available volumes—but it is also less time consuming and labor intensive, and it can be automated. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany.
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway.
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. torsten.schmidt@uni-due.de.
- Centre for Water and Environmental Research, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. torsten.schmidt@uni-due.de.
- IWW Water Centre, Moritzstrasse 26, 45476, Mülheim an der Ruhr, Germany. torsten.schmidt@uni-due.de.
Förderung
- Evonik Industries
- Universität Duisburg-Essen
Zitieren
APA
Lorenzo-Parodi, N., Kaziur-Cegla, W., Gjelstad, A., & Schmidt, T. C. (2023). Liquid-phase microextraction of aromatic amines: hollow fiber–liquid-phase microextraction and parallel artificial liquid membrane extraction comparison. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-023-04579-w
Vancouver
Lorenzo-Parodi N, Kaziur-Cegla W, Gjelstad A, Schmidt TC. Liquid-phase microextraction of aromatic amines: hollow fiber–liquid-phase microextraction and parallel artificial liquid membrane extraction comparison. Analytical and Bioanalytical Chemistry. 2023. doi:10.1007/s00216-023-04579-w
BibTeX
@article{LorenzoParodi2023,
author = {Lorenzo-Parodi, Nerea and Kaziur-Cegla, Wiebke and Gjelstad, Astrid and Schmidt, Torsten C},
title = {Liquid-phase microextraction of aromatic amines: hollow fiber–liquid-phase microextraction and parallel artificial liquid membrane extraction comparison},
journal = {Analytical and Bioanalytical Chemistry},
year = {2023},
doi = {10.1007/s00216-023-04579-w}
}
EUVIMED