EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Membrane‐Based Strategy for the High‐Throughput Determination of Steroidal Hormones in Human Urine Using Natural Deep Eutectic Solvents Combined With Liquid Chromatography Coupled With Diode Array Detector

Lucas Morés, Camila Will, Eduardo Carasek, Josias Merib

Journal of Separation Science · 2025

DOI: 10.1002/jssc.70229 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, 2025. Verfasst von Lucas Morés und 3 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Farmacociências, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil. Hauptthemen laut MEDLINE: Deep Eutectic Solvents, Estrone, Estradiol, Membranes, Artificial. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa e Inovação do Estado de Santa Catarina, Universidade Federal de Ciências da Saúde de Porto Alegre.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Estrogen hormones are present in the human body at varying concentrations, either naturally or through ingestion. At regulated levels, these compounds perform vital functions in the body. However, elevated concentrations are related to deregulation of several processes, such as abnormal cell proliferation, which can lead to the development of cancer (breast and ovarian) and other diseases (endometriosis). In this work, an analytical methodology is proposed for the determination of 17β‐estradiol (E1), estrone (E2), and 17α‐ethinylestradiol (EE2) in human urine. Hollow fiber‐microporous membrane liquid–liquid extraction (HF‐MMLLE) is used with natural deep eutectic solvents (NADESs). This technique was associated with a 96‐well plate system followed by high‐performance liquid chromatography coupled with a diode array detector (HPLC‐DAD). The optimized conditions consisted of using thymol and camphor (1:1 v/v) as extraction solvent; an extraction time of 100 min; acetonitrile as desorption solvent; a desorption time of 30 min; and a sample pH adjusted to 12. Limits of quantification (LOQs) of 25 ng mL −1 for E2 and 50 ng mL −1 for E1 and EE2, and limits of detection (LOD) of 7.5 ng mL −1 for E2 and 15 ng mL −1 for E1 and EE2 were obtained. Intraday and interday precisions were lower than 8.7% and 21.6%, respectively. Relative recoveries were examined in two samples and ranged from 68.2% to 131.8%. The method was applied in samples from healthy volunteers, and concentrations from 75.6 to 182.7 ng mL −1 for E2 were found. Finally, the method was evaluated by two sustainable metrics to examine the green aspects of the experimental approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep Eutectic SolventsEstroneEstradiolMembranes, ArtificialHigh-Throughput Screening AssaysEthinyl EstradiolHumansChromatography, High Pressure LiquidLiquid-Liquid ExtractionSolvents

Stichwörter der Autor:innen

bioanalytical methodsestrogensmicroextractionsustainabilityurine monitoring

Substanzen

Deep Eutectic SolventsEstroneEstradiolMembranes, ArtificialEthinyl EstradiolSolvents

Autor:innen und Institutionen

  • Departamento de Farmacociências, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil.
  • Programa de Pós-Graduação em Biociências, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil.
  • Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, Santa Catarina, Brazil.

Förderung

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Fundação de Amparo à Pesquisa e Inovação do Estado de Santa Catarina
  • Universidade Federal de Ciências da Saúde de Porto Alegre

Zitieren

APA

Morés, L., Will, C., Carasek, E., & Merib, J. (2025). A Membrane‐Based Strategy for the High‐Throughput Determination of Steroidal Hormones in Human Urine Using Natural Deep Eutectic Solvents Combined With Liquid Chromatography Coupled With Diode Array Detector. Journal of Separation Science. https://doi.org/10.1002/jssc.70229

Vancouver

Morés L, Will C, Carasek E, Merib J. A Membrane‐Based Strategy for the High‐Throughput Determination of Steroidal Hormones in Human Urine Using Natural Deep Eutectic Solvents Combined With Liquid Chromatography Coupled With Diode Array Detector. Journal of Separation Science. 2025. doi:10.1002/jssc.70229

BibTeX
@article{Mors2025,
  author = {Morés, Lucas and Will, Camila and Carasek, Eduardo and Merib, Josias},
  title = {A Membrane‐Based Strategy for the High‐Throughput Determination of Steroidal Hormones in Human Urine Using Natural Deep Eutectic Solvents Combined With Liquid Chromatography Coupled With Diode Array Detector},
  journal = {Journal of Separation Science},
  year = {2025},
  doi = {10.1002/jssc.70229}
}
Kostenlos starten →