Fachartikel in der Zeitschrift Journal of Chromatography A, 2025. Verfasst von Amir Abbas Matin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran. Electronic address: matinchem@gmail.com. Hauptthemen laut MEDLINE: Polyvinyls, Liquid Phase Microextraction, Estrogens, Membranes, Artificial. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Azarbaijan Shahid Madani University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A polyvinylidene fluoride (PVDF)-based membrane was developed for high-throughput liquid phase thin film microextraction (LP-TFME) of estrone (E1) and 17β-estradiol (E2) in aqueous and biological samples, followed by quantification using high-performance liquid chromatography with ultraviolet detection (HPLC-UV). The film was fabricated via a two-step casting (TC) process combined with phase inversion and characterized using field emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR), nitrogen adsorption-desorption analysis, and overall porosity measurements. Extraction and desorption conditions were systematically optimized, yielding the following parameters: 1-octanol as the organic solvent, 16 % (w/v) NaCl, stirring rate of 1600 rpm, pH 8, temperature 25 °C, extraction time 35 min, methanol as the desorption solvent, and desorption time 15 min. The method achieved high-throughput efficiency, processing samples at a rate of 0.78 minutes per sample during the extraction-desorption cycle through 64-well plate technology. Under optimized conditions, the method demonstrated linear calibration ranges of 0.5-150 μg L⁻¹ for aqueous samples and 10-150 μg L⁻¹ for both plasma and urine samples for E1 and E2. Limits of detection (LODs) were determined as 0.16 μg L⁻¹ (aqueous) and 3.30 μg L⁻¹ (plasma and urine) for both analytes. Relative standard deviations (RSDs) ranged from 6.87 % to 8.71 %, while enrichment factors reached 46.25 for E2 and 56.19 for E1, highlighting the method's precision and sensitivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolyvinylsLiquid Phase MicroextractionEstrogensMembranes, ArtificialHigh-Throughput Screening AssaysChromatography, High Pressure LiquidHumansReproducibility of ResultsLimit of DetectionSolventsEstradiolLinear ModelsFluorocarbon Polymers

Stichwörter der Autor:innen

17β-estradiolEstroneHigh-throughputMembranePolyvinylidene fluorideThin film microextraction

Substanzen

Polyvinylspolyvinylidene fluorideEstrogensMembranes, ArtificialSolventsEstradiolFluorocarbon Polymers

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran. Electronic address: matinchem@gmail.com.
  • Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran.
  • Department of Cellular and Molecular Biology, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, 53714-161 Tabriz, Iran.

Förderung

  • Azarbaijan Shahid Madani University

Zitieren

APA

Matin, A. A., Teymurlu, A. K., Habibi, B., Safarpour, M., & Najavand, S. (2025). High throughput liquid phase thin film microextraction of estrogens by solvent-loaded polyvinylidene fluoride membrane sheet. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2025.466252

Vancouver

Matin AA, Teymurlu AK, Habibi B, Safarpour M, Najavand S. High throughput liquid phase thin film microextraction of estrogens by solvent-loaded polyvinylidene fluoride membrane sheet. Journal of Chromatography A. 2025. doi:10.1016/j.chroma.2025.466252

BibTeX
@article{Matin2025,
  author = {Matin, Amir Abbas and Teymurlu, Ahad Kazempour and Habibi, Biuck and Safarpour, Mahdie and Najavand, Saeed},
  title = {High throughput liquid phase thin film microextraction of estrogens by solvent-loaded polyvinylidene fluoride membrane sheet},
  journal = {Journal of Chromatography A},
  year = {2025},
  doi = {10.1016/j.chroma.2025.466252}
}
Kostenlos starten →