Ventilation/perfusion mismatch measured by electrical impedance tomography at the bedside: potentialities and challenges

Marco Leali, Shigeki Fujitani, Tommaso Mauri

Intensive Care Medicine · 2026-03 · 52 (3) · 548-551

DOI: 10.1007/s00134-026-08310-y ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Intensive Care Medicine, online erschienen am 26.01.2026. Verfasst von Marco Leali und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Ministero della Salute, Università degli Studi di Milano.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

for stabilization and to estimate the apnea-related drift in impedance [4], then ~ 10 ml of contrast agent is pushed through a central line in < 1-2 s.Apnea normally lasts ≥ 8 s [6], but longer times have been used experimentally and may sometimes be advisable.Three components are typically combined in most thoracic perfusion traces, termed [4, 5] pre-lung-likely corresponding to the right heart and greater pulmonary vessels-lung and post-lung-encompassing an early left heart rebound, bronchial circulation and recirculation [5] (Fig. 1b).Approximate peak times for each component depend on hemodynamics [7] and have been reported in swine [5,7], while only inferred from physiology in humans.The low spatial resolution of EIT magnifies the partial volume effect (PVE), which must be addressed by post-processing.Several algorithms are in use to isolate and reconstruct lung perfusion images, greatly differing in how they deal with PVE.The best validated [4,5,7] fit multiple gamma variates to data, only to retain the lung signal.Others remove a cluster of cardiac pixels or manually select a time frame between the pre-lung and lung peaks.Irrespective of the algorithm, regional perfusion is assumed to be proportional to the maximum upslope of the indicator signal, disregarding wash-out (Fig. 1b, e) [5].To date, the need for stable apnea warrants caution when analyzing indicator-based V′/Q by EIT in spontaneously breathing patients [6,8].Alternatively, the pulmonary pulse can be isolated from EIT.However, while related to stroke volume passing from the heart to lung

Schlagwörter

Stichwörter der Autor:innen

Electrical impedance tomographyLungPerfusionVentilation

Autor:innen und Institutionen

  • Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
  • . Marianna University School of Medicine, Kawasaki, Japan.
  • Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy. tommaso.mauri@unimi.it.
  • Department of Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy. tommaso.mauri@unimi.it.

Förderung

  • Ministero della Salute
  • Università degli Studi di Milano

Zitieren

APA

Leali, M., Fujitani, S., & Mauri, T. (2026). Ventilation/perfusion mismatch measured by electrical impedance tomography at the bedside: potentialities and challenges. Intensive Care Medicine, 52(3), 548-551. https://doi.org/10.1007/s00134-026-08310-y

Vancouver

Leali M, Fujitani S, Mauri T. Ventilation/perfusion mismatch measured by electrical impedance tomography at the bedside: potentialities and challenges. Intensive Care Medicine. 2026;52(3):548-551. doi:10.1007/s00134-026-08310-y

BibTeX
@article{Leali2026,
  author = {Leali, Marco and Fujitani, Shigeki and Mauri, Tommaso},
  title = {Ventilation/perfusion mismatch measured by electrical impedance tomography at the bedside: potentialities and challenges},
  journal = {Intensive Care Medicine},
  year = {2026},
  volume = {52},
  number = {3},
  pages = {548--551},
  doi = {10.1007/s00134-026-08310-y}
}
Kostenlos starten →