EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

Early bedside detection of pulmonary perfusion defect by electrical impedance tomography after pulmonary endarterectomy

Qianlin Wang iD, Huaiwu He iD, Siyi Yuan, Jing Jiang, Yi Chi, Yun Long, Zhanqi Zhao

Pulmonary Circulation · 2024-04 · 14 (2)

DOI: 10.1002/pul2.12372 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Pulmonary Circulation, 2024-05. Verfasst von Qianlin Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases Peking Union Medical College Hospital, Chinese Academy…. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pulmonary endarterectomy (PEA) is the standard treatment for chronic thromboembolic pulmonary hypertension. However, it poses risks of perioperative vascular complications, which can lead to serious clinical outcomes. This study introduces a novel noninvasive and radiation‐free clinical imaging tool, electrical impedance tomography (EIT), for real‐time bedside assessment of lung perfusion after PEA. It identifies ventilation‐perfusion mismatches arising from postoperative complications, particularly valuable for patients with hemodynamic instability, thus eliminating risks tied to CT room transfers. The article reports a case where EIT was used to identify an in‐situ thrombosis post‐PEA, marking the first such application. The emphasis is on early detection using EIT, which offers a promising approach for therapeutic interventions and improved postoperative evaluations.

Schlagwörter

Stichwörter der Autor:innen

critical careelectrical impedance tomographypulmonary endarterectomypulmonary perfusion

Autor:innen und Institutionen

  • Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases Peking Union Medical College Hospital, Chinese Academy of Medical Sciences Beijing China.
  • Department of Critical Care Medicine Chongqing General Hospital Chongqing Liangjiang New Area China.
  • Institute of Technical Medicine Furtwangen University Villingen-Schwenningen Germany.

ORCID-Profile: Qianlin Wang, Huaiwu He

Förderung

  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Wang, Q., He, H., Yuan, S., Jiang, J., Chi, Y., Long, Y., & Zhao, Z. (2024). Early bedside detection of pulmonary perfusion defect by electrical impedance tomography after pulmonary endarterectomy. Pulmonary Circulation, 14(2). https://doi.org/10.1002/pul2.12372

Vancouver

Wang Q, He H, Yuan S, Jiang J, Chi Y, Long Y, et al. Early bedside detection of pulmonary perfusion defect by electrical impedance tomography after pulmonary endarterectomy. Pulmonary Circulation. 2024;14(2). doi:10.1002/pul2.12372

BibTeX
@article{Wang2024,
  author = {Wang, Qianlin and He, Huaiwu and Yuan, Siyi and Jiang, Jing and Chi, Yi and Long, Yun and Zhao, Zhanqi},
  title = {Early bedside detection of pulmonary perfusion defect by electrical impedance tomography after pulmonary endarterectomy},
  journal = {Pulmonary Circulation},
  year = {2024},
  volume = {14},
  number = {2},
  doi = {10.1002/pul2.12372}
}
Kostenlos starten →