EUVIMEDEUVIMED entdecken
Crossref

Evaluation of a novel abdominal compression airbag for respiratory motion management and setup reproducibility in upper abdominal radiotherapy

Yinghua Shi iD, Huidong Wang iD, Lijuan Ding, Minghui Sun, Peilin Li, Wei Hou, Yu Li, Yan Gao, Wuji Sun iD

Strahlentherapie und Onkologie · 24.07.2026

DOI: 10.1007/s00066-026-02577-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Strahlentherapie und Onkologie, online erschienen am 24.07.2026. Verfasst von Yinghua Shi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, China. Die Arbeit nennt 37 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to evaluate the clinical feasibility and efficacy of a novel abdominal compression airbag (ACA) for respiratory motion management and setup reproducibility in upper abdominal radiotherapy and to compare its performance against free breathing (FB) and the standard abdominal compression plate (ACP).

Methods

A total of 54 patients with upper abdominal malignancies were retrospectively analyzed in three groups based on the FB, ACP, and ACA motion management strategies. Respiratory motion amplitude was quantified by calculating the displacement of the liver centroid between the 0% and 50% phases of four-dimensional CT scans. Interfractional setup reproducibility was assessed by analyzing setup errors derived from pretreatment cone-beam CT (CBCT) scans. Statistical comparisons for the respiratory motion amplitude were performed using the Kruskal–Wallis test followed by Dunn’s post-hoc test. The analysis of setup stability utilized a linear mixed-effects model.

Results

Both ACP and ACA significantly attenuated respiratory motion compared to FB ( p < 0.001). The mean vectorial motion amplitudes were 0.88 ± 0.20 cm, 0.61 ± 0.24 cm, and 0.57 ± 0.19 cm for the FB, ACP, and ACA groups, respectively. No significant difference in motion restriction was found between ACA and ACP. In terms of setup reproducibility, the ACA group demonstrated superior stability in the anterior–posterior direction, with the lowest mean absolute error (0.15 ± 0.11 cm), but exhibited larger errors in the left–right direction (0.32 ± 0.22 cm) compared to both FB (0.18 ± 0.15 cm) and ACP (0.19 ± 0.15 cm).

Conclusion

The ACA achieved a motion restriction performance comparable to the standard ACP, but it was associated with increased uncertainty in the left–right direction. The ACA could serve as a practical alternative with potential workflow and compatibility advantages, preferably coupled with robust image-guided verification to maintain setup stability.

Schlagwörter

Stichwörter der Autor:innen

Abdominal compression plateInterfractional variationIntrafractional motionPatient immobilizationStereotactic body radiation therapy (SBRT)Thermoplastic mask

Autor:innen und Institutionen

  • Department of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, China.
  • Jilin Provincial Key Laboratory of Radiation Oncology & Therapy, Department of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, China.
  • NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, China.
  • Department of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, China. sunwuji@126.com.

ORCID-Profile: Yinghua Shi, Huidong Wang, Wuji Sun

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Shi, Y., Wang, H., Ding, L., Sun, M., Li, P., Hou, W., Li, Y., Gao, Y., & Sun, W. (2026). Evaluation of a novel abdominal compression airbag for respiratory motion management and setup reproducibility in upper abdominal radiotherapy. Strahlentherapie und Onkologie. https://doi.org/10.1007/s00066-026-02577-2

Vancouver

Shi Y, Wang H, Ding L, Sun M, Li P, Hou W, et al. Evaluation of a novel abdominal compression airbag for respiratory motion management and setup reproducibility in upper abdominal radiotherapy. Strahlentherapie und Onkologie. 2026. doi:10.1007/s00066-026-02577-2

BibTeX
@article{Shi2026,
  author = {Shi, Yinghua and Wang, Huidong and Ding, Lijuan and Sun, Minghui and Li, Peilin and Hou, Wei and Li, Yu and Gao, Yan and Sun, Wuji},
  title = {Evaluation of a novel abdominal compression airbag for respiratory motion management and setup reproducibility in upper abdominal radiotherapy},
  journal = {Strahlentherapie und Onkologie},
  year = {2026},
  doi = {10.1007/s00066-026-02577-2}
}
Kostenlos starten →