EUVIMEDEUVIMED entdecken
Crossref

The catalytic stripping voltammetre of trace copper (II) at a chemically modified electrode on oxine containing carbon paste

W J Qiao, H Dina

Journal of Tongji Medical University · 1993

DOI: 10.1007/bf02886515 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Tongji Medical University, 1993. Verfasst von W J Qiao und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Tongji Medical University, Wuhan. Hauptthemen laut MEDLINE: Electrodes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 3 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An oxine modified electrode is prepared on the basis of carbon paste. The process is rapid and simple. The catalytic stripping voltammetric characteristic of Cu(II) on the modified electrode was studied and the method has been applied to the determination of trace Cu(II), and there was good linear relationship between the concentration of Cu(II) and the peak height in the concentration range of 1.5 x 10(-)-1.5 x 10(-6) mol/L for Cu(II). We have detected the copper content of human hair and blood with satisfactory results. Moreover, the reaction mechanism of the modified electrode was discussed. It was found that the improvement of sensitivity and selection of the modified electrode was dependent of the complex adsorbing property of the electrode surface and the sensitive catalytic hydrogen wave produce.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrodesCarbonCopperElectrochemistryHairHumansHydrogen-Ion ConcentrationOxyquinoline

Substanzen

OxyquinolineCarbonCopper

Autor:innen und Institutionen

  • Department of Chemistry, Tongji Medical University, Wuhan.

Zitieren

APA

Qiao, W. J., & Dina, H. (1993). The catalytic stripping voltammetre of trace copper (II) at a chemically modified electrode on oxine containing carbon paste. Journal of Tongji Medical University. https://doi.org/10.1007/bf02886515

Vancouver

Qiao WJ, Dina H. The catalytic stripping voltammetre of trace copper (II) at a chemically modified electrode on oxine containing carbon paste. Journal of Tongji Medical University. 1993. doi:10.1007/bf02886515

BibTeX
@article{Qiao1993,
  author = {Qiao, W J and Dina, H},
  title = {The catalytic stripping voltammetre of trace copper (II) at a chemically modified electrode on oxine containing carbon paste},
  journal = {Journal of Tongji Medical University},
  year = {1993},
  doi = {10.1007/bf02886515}
}
Kostenlos starten →