Simultaneous voltammetric determination of 3-methyladenine and adenine at disposable screen-printed carbon electrode
Analytical Biochemistry · 2025
DOI: 10.1016/j.ab.2025.115863 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Biochemistry, 2025. Verfasst von José Gouveia S Neto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, 52171-900, Brazil; Fundamental Chemistry Department, Federal University …. Hauptthemen laut MEDLINE: Adenine, Carbon, Electrochemical Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 70 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, National Council for Scientific and Technological Development.
Abstract (Originalsprache)
The anodic behavior of 3-methyladenine (3-mAde) and adenine (Ade) were investigated in aqueous media on commercial screen-printed carbon electrodes (SPCEs), using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The electrochemical performance of the SPCEs was first evaluated by CV and using the [Fe(CN)6]3- redox probe. The electroactive areas of some SPCEs were also determined and discussed. Overall, the results were very satisfactory and indicated good repeatability and reproducibility of the SPCEs. Regarding 3-mAde its oxidation occurred in a single irreversible step pH dependent controlled by a diffusion layer and at more positive potential, ∼ +200.00 mV, in relation to Ade, demonstrating the possibility of simultaneous detection of these two biomarkers. By DPV experimental conditions were explored to increase the sensitivity and selectivity of the 3-mAde electrooxidation signal, such as influence of the composition and pH of the medium, effect of 3-mAde concentration and presence of possible interferents. A simple, sensitive, selective and fast electroanalytical method, using DPV and commercial SPCE, was developed for determination of 3-mAde in hydrolyzed DNA samples; with a linear range from 2.00 to 10.00 μmol L-1, limit of detection (LOD) of 0.35 μmol L-1 and recoveries ranged from 96.0 % to 98.3 % in acetate buffer (pH = 4.10). For the simultaneous quantification of Ade and 3-mAde the analytical data were: concentration range of 0.50-10.00 μmol L-1, LOD of 0.34 μmol L-1 and the mean recovery was 95.2 % for Ade and from 2.00 to 10.00 μmol L-1, LOD of 0.64 μmol L-1 and the mean recovery was 101.3 % for 3-mAde.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, 52171-900, Brazil; Fundamental Chemistry Department, Federal University of Pernambuco, Recife, PE, 50740-560, Brazil.
- Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, 52171-900, Brazil.
- Fundamental Chemistry Department, Federal University of Pernambuco, Recife, PE, 50740-560, Brazil.
- Department of Chemistry, Federal Rural University of Pernambuco, Recife, PE, 52171-900, Brazil. Electronic address: s.carlosb.oliveira@gmail.com.
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- National Council for Scientific and Technological Development
Zitieren
APA
Neto, J. G. S., Rodrigues, W. E., Diniz, É. M. P., Dos Santos, V. B., & Oliveira, S. C. B. (2025). Simultaneous voltammetric determination of 3-methyladenine and adenine at disposable screen-printed carbon electrode. Analytical Biochemistry. https://doi.org/10.1016/j.ab.2025.115863
Vancouver
Neto JGS, Rodrigues WE, Diniz ÉMP, Dos Santos VB, Oliveira SCB. Simultaneous voltammetric determination of 3-methyladenine and adenine at disposable screen-printed carbon electrode. Analytical Biochemistry. 2025. doi:10.1016/j.ab.2025.115863
BibTeX
@article{Neto2025,
author = {Neto, José Gouveia S and Rodrigues, Wellington Eneias and Diniz, Éverton Marcelo P and Dos Santos, Vagner B and Oliveira, Severino Carlos B},
title = {Simultaneous voltammetric determination of 3-methyladenine and adenine at disposable screen-printed carbon electrode},
journal = {Analytical Biochemistry},
year = {2025},
doi = {10.1016/j.ab.2025.115863}
}
EUVIMED