Angiographic assessment of dimensions of 6F and 7F Mallinckrodt Softouch® coronary contrast catheters from digital and cine arteriograms
The International Journal of Cardiac Imaging · 1992
DOI: 10.1007/bf01137536 ↗Kurz gefasst
Fachartikel in der Zeitschrift The International Journal of Cardiac Imaging, 1992. Verfasst von G Koning und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology and Nuclear Medicine, University Hospital Leiden, The Netherlands. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 6 Literaturangaben.
Abstract (Originalsprache)
Coronary contrast catheters are almost exclusively used for calibration purposes in quantitative coronary arteriography. In this study we have assessed the suitability of new 6F and 7F Mallinckrodt nylon catheter with Softouch tip with improved imaging specifications for such calibration purposes both from digital and cinefilm images using new analytical QCA-software packages (Philips DCI/ACA and Medis CMS). The average signed differences between the angiographically measured dimensions at 100% contrast fillings and acquired at 3 different kV-levels (60, 75 and 90 kV) were -3.3% and 0.6% for the 6F and 7F catheter tips, respectively as measured with the ACA-package on digital images, and -0.4% and 2.1%, respectively, as measured with the CMS-system on cinefilm images. The pooled standard deviations were 0.102 mm and 0.107 mm for the 6F and 7F catheter tips, respectively, as measured with the ACA-package, and 0.080 mm and 0.083 mm, as measured with the CMS-system. The deviations for the nylon shafts were much larger. It became also clear that neither the filling of the catheters, nor the kV-level used, had any appreciable effect on the measurement accuracy for the Softouch tips, which facilitates the frame selection in QCA-studies. From these data it can be concluded that the nontapering parts of the 6F and 7F Mallinckrodt Softouch tips are very well suitable for QCA calibration purposes, but that the nylon shafts are not.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Diagnostic Radiology and Nuclear Medicine, University Hospital Leiden, The Netherlands.
Zitieren
APA
Koning, G., van der Zwet, P. M., von Land, C. D., & Reiber, J. H. (1992). Angiographic assessment of dimensions of 6F and 7F Mallinckrodt Softouch® coronary contrast catheters from digital and cine arteriograms. The International Journal of Cardiac Imaging. https://doi.org/10.1007/bf01137536
Vancouver
Koning G, van der Zwet PM, von Land CD, Reiber JH. Angiographic assessment of dimensions of 6F and 7F Mallinckrodt Softouch® coronary contrast catheters from digital and cine arteriograms. The International Journal of Cardiac Imaging. 1992. doi:10.1007/bf01137536
BibTeX
@article{Koning1992,
author = {Koning, G and van der Zwet, P M and von Land, C D and Reiber, J H},
title = {Angiographic assessment of dimensions of 6F and 7F Mallinckrodt Softouch® coronary contrast catheters from digital and cine arteriograms},
journal = {The International Journal of Cardiac Imaging},
year = {1992},
doi = {10.1007/bf01137536}
}
EUVIMED