EUVIMEDDescoperă EUVIMED
Crossref

A new experimental approach for monitoring postoperative bypass patency after coronary artery bypass grafting

M Lass, K Paulat, R Brucher, C Hübner, P Schmid, U Uetz, A Hannekum

International Journal of Clinical Monitoring and Computing · 1994

DOI: 10.1007/bf01132844 ↗

At a glance

Journal article in International Journal of Clinical Monitoring and Computing, 1994. Written by M Lass and 6 co-authors. Institution: Department of Cardiac Surgery, University of Ulm, Germany. Major MEDLINE topics: Coronary Artery Bypass, Prostheses and Implants, Rheology. Cited 1 times so far (Crossref); 8 references.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Little information is known concerning hemodynamic parameters of bypass grafts after open heart surgery during the postoperative period. As there is no easy to use bedside-method for monitoring, we developed a new implantable Doppler probe to measure blood flow velocity with a 20 MHz pulsed Doppler system. The accuracy of this method was proved in a circulatory model and in animal studies. Our conclusion is that the implantable pulsed Doppler system is a sensitive method for monitoring small vessel hemodynamics.

Subjects

MeSH terms (MEDLINE)

Coronary Artery BypassProstheses and ImplantsRheologyAnimalsBlood Flow VelocityBlood VolumeCalibrationDogsEquipment DesignMammary ArteriesModels, CardiovascularMonitoring, PhysiologicReproducibility of ResultsTransducersUltrasonographyVascular Patency

Authors and institutions

  • Department of Cardiac Surgery, University of Ulm, Germany.

Cite

APA

Lass, M., Paulat, K., Brucher, R., Hübner, C., Schmid, P., Uetz, U., & Hannekum, A. (1994). A new experimental approach for monitoring postoperative bypass patency after coronary artery bypass grafting. International Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/bf01132844

Vancouver

Lass M, Paulat K, Brucher R, Hübner C, Schmid P, Uetz U, et al. A new experimental approach for monitoring postoperative bypass patency after coronary artery bypass grafting. International Journal of Clinical Monitoring and Computing. 1994. doi:10.1007/bf01132844

BibTeX
@article{Lass1994,
  author = {Lass, M and Paulat, K and Brucher, R and Hübner, C and Schmid, P and Uetz, U and Hannekum, A},
  title = {A new experimental approach for monitoring postoperative bypass patency after coronary artery bypass grafting},
  journal = {International Journal of Clinical Monitoring and Computing},
  year = {1994},
  doi = {10.1007/bf01132844}
}
Start for free →