Development and Validation of a Low-Cost, High-Fidelity Simulation Model for Robotic Internal Mammary Artery Harvest Using the da Vinci Xi Robot
Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2024
DOI: 10.1177/15569845241286012 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2024. Verfasst von Syed Faaz Ashraf und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, University of Pittsburgh School of Medicine, PA, USA. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Mammary Arteries. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 13 Literaturangaben. Gefördert von: Division of Intramural Research, Society of Thoracic Surgeons.
Abstract (Originalsprache)
Objective
We created and validated a low-cost simulation model for robotic internal mammary artery (IMA) takedown.
Methods
The simulation model utilized a calf fetus thorax cavity stented open internally and secured to a table. The simulation model was validated at a 2-day robotic cardiac surgery workshop. Each participant harvested one IMA using the da Vinci Xi robot (Intuitive Surgical, Sunnyvale, CA, USA). We compared participant self-reported confidence at robotic IMA harvest before and after using the simulator.
Results
Our novel thorax-securing strategy resulted in a stable structure and allowed access to both IMAs from the same 3 ports. The cost to set up the first simulation model was $176 and $133 for every subsequent model. Fifty participants used the simulation model: 42 cardiothoracic surgery attendings and 8 fellows or residents. The feedback form response rate was 78% ( n = 39). On the Likert scale, participants rated realism of the calf model to simulate robotic IMA harvesting (0 = not realistic , 10 = highly realistic ) with a median of 8 out of 10 (interquartile range [IQR] 7 to 9). Participant confidence (0 = not at all confident , 10 = very confident ) in robotic IMA harvesting before and after using the simulator increased ( P = 0.001) from a median of 5 (IQR 1 to 7) to 9 (IQR 7 to 10).
Conclusions
This robotic IMA harvest simulation model is affordable, realistic, and improved participant confidence in robotic IMA harvest. It may provide a valuable training tool for surgeons learning robotic coronary bypass surgery and allows for training frequency necessary to pass basic learning curves.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiothoracic Surgery, University of Pittsburgh School of Medicine, PA, USA.
- Department of Cardiovascular Surgery, Saint Thomas West Hospital, Nashville, TN, USA.
- Department of Cardiothoracic Surgery, University of Chicago Medicine, IL, USA.
- Department of Surgery, UC Davis Health, Sacramento, CA, USA.
- Georgia Heart Institute at Northeast Georgia Medical Center, Gainesville, GA, USA.
ORCID-Profile: Syed Faaz Ashraf, Husam H Balkhy
Förderung
- Division of Intramural Research
- Society of Thoracic Surgeons
Zitieren
APA
Ashraf, S. F., Seese, L., Hasan, I. S., Babu, A. N., Balkhy, H. H., Kiaii, B. B., Guy, T. S., Kaczorowski, D. J., & Bonatti, J. (2024). Development and Validation of a Low-Cost, High-Fidelity Simulation Model for Robotic Internal Mammary Artery Harvest Using the da Vinci Xi Robot. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. https://doi.org/10.1177/15569845241286012
Vancouver
Ashraf SF, Seese L, Hasan IS, Babu AN, Balkhy HH, Kiaii BB, et al. Development and Validation of a Low-Cost, High-Fidelity Simulation Model for Robotic Internal Mammary Artery Harvest Using the da Vinci Xi Robot. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2024. doi:10.1177/15569845241286012
BibTeX
@article{Ashraf2024,
author = {Ashraf, Syed Faaz and Seese, Laura and Hasan, Irsa S and Babu, Ashok N and Balkhy, Husam H and Kiaii, Bob B and Guy, T Sloane and Kaczorowski, David J and Bonatti, Johannes},
title = {Development and Validation of a Low-Cost, High-Fidelity Simulation Model for Robotic Internal Mammary Artery Harvest Using the da Vinci Xi Robot},
journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
year = {2024},
doi = {10.1177/15569845241286012}
}
EUVIMED