Reflectance pulse oximetry in fetal lambs: Subcutaneous vessels and vasoconstriction affect its reliability
Journal of Clinical Monitoring · 1996
DOI: 10.1007/bf00857643 ↗At a glance
Journal article in Journal of Clinical Monitoring, 1996. Written by R Nijland and 3 co-authors. Institution: Department of Obstetrics & Gynaecology, University Hospital Nijmegen, The Netherlands. Major MEDLINE topics: Fetal Blood, Fetal Monitoring. Cited 6 times so far (Crossref); 20 references.
Abstract (original language)
OBJECTIVE: Reflectance pulse oximetry (RPOX) has been introduced for intrapartum fetal surveillance. The purpose of this study was to describe two possible effects on the reliability of RPOX, namely the effect of the presence of a subcutaneous vein and the effect of vasoconstriction by adrenaline, both at fetal SaO2 levels. METHODS: In four anesthetized fetal lambs, a prototype 660/890 nm reflectance sensor (Nellcor Inc.) was placed on the fetal head, with the photodiode of the sensor precisely over a superficial subcutaneous vein. Measurements were made before and after coagulation of the vein. In five anesthetized fetal lambs, one or two reflectance sensors were placed on the fetal head and/or neck and adrenaline was administered in doses of 0.02 to 0.04 mg via a brachial artery. Pulse oximeter saturation readings (SpO2) were compared with continuous arterial oxygen saturation (SaO2) values obtained using a fiberoptic catheter (Opticath, Abbott) in the carotid artery. RESULTS: When the sensor was placed over the vein, the pulse oximeter read 18% to 24% too low at a SaO2 level of 20% to 50%. After coagulation of the vein, SpO2 readings were in agreement with fiberoptic SaO2 values. Administration of adrenaline resulted in a large overestimation of the SaO2 in 6 of the 7 measurements. CONCLUSIONS: Subcutaneous veins and vasoconstriction can affect the reliability of reflectance pulse oximetry. As comparable situations may occur during labor, SpO2 readings should be interpreted with caution when this kind or comparable types of RPOX sensors are used at low SaO2 levels.
Subjects
MeSH terms (MEDLINE)
Substances
Authors and institutions
- Department of Obstetrics & Gynaecology, University Hospital Nijmegen, The Netherlands.
Cite
APA
Nijland, R., Jongsma, H. W., Verbruggen, I. M., & Nijhuis, J. G. (1996). Reflectance pulse oximetry in fetal lambs: Subcutaneous vessels and vasoconstriction affect its reliability. Journal of Clinical Monitoring. https://doi.org/10.1007/bf00857643
Vancouver
Nijland R, Jongsma HW, Verbruggen IM, Nijhuis JG. Reflectance pulse oximetry in fetal lambs: Subcutaneous vessels and vasoconstriction affect its reliability. Journal of Clinical Monitoring. 1996. doi:10.1007/bf00857643
BibTeX
@article{Nijland1996,
author = {Nijland, R and Jongsma, H W and Verbruggen, I M and Nijhuis, J G},
title = {Reflectance pulse oximetry in fetal lambs: Subcutaneous vessels and vasoconstriction affect its reliability},
journal = {Journal of Clinical Monitoring},
year = {1996},
doi = {10.1007/bf00857643}
}
EUVIMED