Toward implementation of lactate compared with pH in fetal scalp blood sampling during labor: A clinical comparative single‐center study
Acta Obstetricia et Gynecologica Scandinavica · 2026
DOI: 10.1111/aogs.70329 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Acta Obstetricia et Gynecologica Scandinavica, 2026. Verfasst von Suzanne J van Woudenberg und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynaecology, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Scalp, Lactic Acid, Fetal Blood, Fetal Hypoxia. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Since 60 years, pH measurement in fetal scalp blood samples (FBS) is used to diagnose fetal hypoxia during labor, although the last three decades lactate measurement in FBS has been increasingly used as a safe alternative with a lower chance of failure. However, studies demonstrating the direct relation between lactate and pH in FBS with the currently used measurement systems are lacking. Therefore, clinical acceptance and implementation is impeded. This study investigated the relation between lactate and pH in FBS and derived an appropriate lactate cutoff value. Material and Methods This observational prospective single‐center study included 263 FBS in the period of 8 months. After collection of FBS, pH was assessed first (iSTAT®), after which lactate was assessed (StatStrip® Lactate 2). Clinical decisions were based on pH results only. Our primary objective was to assess the correlation between lactate and pH in FBS and to establish a lactate cutoff value for ruling out a low Apgar score at 5 minutes and neonatal acidosis, with corresponding sensitivity and specificity as secondary outcomes. Diagnostic performance of lactate was assessed by using the area under the curve (AUC) of the receiver operation characteristic curve (ROC curve), from which cutoff values were derived.
Results
In FBS, lactate and pH showed a moderate inverse linear correlation ( r = −0.53). The AUC of the ROC curve was 0.88 (0.83–0.93), indicating a good diagnostic performance of lactate to identify an abnormal pH (pH
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Obstetrics and Gynaecology, Utrecht, The Netherlands.
- Department of Obstetrics and Gynaecology, Arnhem, The Netherlands.
- Department of Clinical Chemistry, Arnhem, The Netherlands.
- Clinical Research Center, Arnhem, The Netherlands.
ORCID-Profile: Suzanne J van Woudenberg, Lian Roovers
Zitieren
APA
van Woudenberg, S. J., Mijnheer, I., van Borren, M. M. G. J., Roovers, L., & Janse, F. (2026). Toward implementation of lactate compared with pH in fetal scalp blood sampling during labor: A clinical comparative single‐center study. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.70329
Vancouver
van Woudenberg SJ, Mijnheer I, van Borren MMGJ, Roovers L, Janse F. Toward implementation of lactate compared with pH in fetal scalp blood sampling during labor: A clinical comparative single‐center study. Acta Obstetricia et Gynecologica Scandinavica. 2026. doi:10.1111/aogs.70329
BibTeX
@article{vanWoudenberg2026,
author = {van Woudenberg, Suzanne J and Mijnheer, Ivonne and van Borren, Marcel M G J and Roovers, Lian and Janse, Femi},
title = {Toward implementation of lactate compared with pH in fetal scalp blood sampling during labor: A clinical comparative single‐center study},
journal = {Acta Obstetricia et Gynecologica Scandinavica},
year = {2026},
doi = {10.1111/aogs.70329}
}
EUVIMED