EUVIMEDScopri EUVIMED
Crossref

The Erlanger Microlightguioe Photometer: A new concept for monitoring intracapillary oxygen supply of tissue — First results and a review of the physiological basis

S Kuchenreuther, J Adler, W Schütz, O Eichelbrönner, M Georgieff

Journal of Clinical Monitoring · 1996

DOI: 10.1007/bf00857642 ↗

At a glance

Journal article in Journal of Clinical Monitoring, 1996. Written by S Kuchenreuther and 4 co-authors. Institution: Department of Anesthesiology, University Hospital Ulm, Germany. Cited 15 times so far (Crossref); 25 references.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

The local oxygen supply to the skin immediately before and after withdrawal of blood was appraised in 18 healthy test subjects by measuring the intracapillary hemoglobin oxygenation (HbO2). The investigation was carried out with the Erlanger Microlightguide Photometer (EMPHO). EMPHO measurements are based on the registration of tissue remission spectra from which the HbO2 values are calculated using the Kubelka-Munk theory. The results show that global parameters do not reflect the supply of oxygen to the tissue; for example, in hypovolemia, the physiological response to the pathophysiological stimulus is centralization. This is manifested at a very early stage in the skin, before the oxygen supply to other organs (e.g., liver, kidney, gut) is affected. The disturbance of the local cutaneous oxygen supply is reflected in a change in the intracapillary hemoglobin oxygenation of the skin. Hence, one might consider measurements of the local oxygen supply to the skin as an early indicator for centralization.

Subjects

MeSH terms (MEDLINE)

HemoglobinometryHumansMonitoring, PhysiologicOxygenSkinSpectrophotometry

Substances

Oxygen

Authors and institutions

  • Department of Anesthesiology, University Hospital Ulm, Germany.

Cite

APA

Kuchenreuther, S., Adler, J., Schütz, W., Eichelbrönner, O., & Georgieff, M. (1996). The Erlanger Microlightguioe Photometer: A new concept for monitoring intracapillary oxygen supply of tissue — First results and a review of the physiological basis. Journal of Clinical Monitoring. https://doi.org/10.1007/bf00857642

Vancouver

Kuchenreuther S, Adler J, Schütz W, Eichelbrönner O, Georgieff M. The Erlanger Microlightguioe Photometer: A new concept for monitoring intracapillary oxygen supply of tissue — First results and a review of the physiological basis. Journal of Clinical Monitoring. 1996. doi:10.1007/bf00857642

BibTeX
@article{Kuchenreuther1996,
  author = {Kuchenreuther, S and Adler, J and Schütz, W and Eichelbrönner, O and Georgieff, M},
  title = {The Erlanger Microlightguioe Photometer: A new concept for monitoring intracapillary oxygen supply of tissue — First results and a review of the physiological basis},
  journal = {Journal of Clinical Monitoring},
  year = {1996},
  doi = {10.1007/bf00857642}
}
Start for free →