EUVIMEDEUVIMED entdecken
Crossref

The Erlanger Microlightguioe Photometer: A new concept for monitoring intracapillary oxygen supply of tissue — First results and a review of the physiological basis

S Kuchenreuther, J Adler, W Schütz, O Eichelbrönner, M Georgieff

Journal of Clinical Monitoring · 1996

DOI: 10.1007/bf00857642 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Monitoring, 1996. Verfasst von S Kuchenreuther und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, University Hospital Ulm, Germany. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The local oxygen supply to the skin immediately before and after withdrawal of blood was appraised in 18 healthy test subjects by measuring the intracapillary hemoglobin oxygenation (HbO2). The investigation was carried out with the Erlanger Microlightguide Photometer (EMPHO). EMPHO measurements are based on the registration of tissue remission spectra from which the HbO2 values are calculated using the Kubelka-Munk theory. The results show that global parameters do not reflect the supply of oxygen to the tissue; for example, in hypovolemia, the physiological response to the pathophysiological stimulus is centralization. This is manifested at a very early stage in the skin, before the oxygen supply to other organs (e.g., liver, kidney, gut) is affected. The disturbance of the local cutaneous oxygen supply is reflected in a change in the intracapillary hemoglobin oxygenation of the skin. Hence, one might consider measurements of the local oxygen supply to the skin as an early indicator for centralization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemoglobinometryHumansMonitoring, PhysiologicOxygenSkinSpectrophotometry

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Anesthesiology, University Hospital Ulm, Germany.

Zitieren

APA

Kuchenreuther, S., Adler, J., Schütz, W., Eichelbrönner, O., & Georgieff, M. (1996). The Erlanger Microlightguioe Photometer: A new concept for monitoring intracapillary oxygen supply of tissue — First results and a review of the physiological basis. Journal of Clinical Monitoring. https://doi.org/10.1007/bf00857642

Vancouver

Kuchenreuther S, Adler J, Schütz W, Eichelbrönner O, Georgieff M. The Erlanger Microlightguioe Photometer: A new concept for monitoring intracapillary oxygen supply of tissue — First results and a review of the physiological basis. Journal of Clinical Monitoring. 1996. doi:10.1007/bf00857642

BibTeX
@article{Kuchenreuther1996,
  author = {Kuchenreuther, S and Adler, J and Schütz, W and Eichelbrönner, O and Georgieff, M},
  title = {The Erlanger Microlightguioe Photometer: A new concept for monitoring intracapillary oxygen supply of tissue — First results and a review of the physiological basis},
  journal = {Journal of Clinical Monitoring},
  year = {1996},
  doi = {10.1007/bf00857642}
}
Kostenlos starten →