Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid
European Journal of Nuclear Medicine · 1995-06 · 22 (6) · 532-536
DOI: 10.1007/bf00817277 ↗At a glance
Vergleichsstudie in European Journal of Nuclear Medicine, 1995-06. Written by A Biggi and 4 co-authors. Institution: Department of Nuclear Medicine, S. Croce General Hospital, Cuneo, Italy. Major MEDLINE topics: Chromium Radioisotopes, Edetic Acid, Glomerular Filtration Rate, Technetium Tc 99m Pentetate. Cited 32 times so far (Crossref); 13 references.
Abstract (original language)
Simultaneous measurements of the clearance rate of chromium-51 ethylene diamine tetra-acetic acid (51Cr-EDTA) and technetium-99m diethylene triamine penta-acetic acid (99mTc-DTPA) were performed in 54 patients with a range of function between 9 and 176 ml/min. Using multiple blood samples the two clearance values correlated well (r = 0.97, SEE 8.6 ml/min) and DTPA clearance was higher by 2.9%. For each radiopharmaceutical the plasma clearance rates obtained using multiple blood samples were compared with those obtained with simplified methods, i.e., the 60-180 min two-sample method of Russell and the mono-exponential method with the Brochner-Mortensen correction. For both radiopharmaceuticals the clearance values correlated well with the Russell method (r = 0.99, SEE = 4.1 ml/min for EDTA; r = 0.99, SEE 4.9 ml/min for DTPA) and the mono-exponential method (r = 0.99, SEE 3.6 ml/min for EDTA; r = 0.99, SEE 3.9 ml/min for DTPA). The mean plasma clearance obtained using multiple blood samples did not differ significantly from that obtained with the Russell method, either in patients with a glomerular filtration rate (GFR) or = 30 ml/min. The mean plasma clearance obtained using multiple blood samples differed significantly from that obtained with the mono-exponential method because of the great difference observed in patients with GFR > or = 30 ml/min. It is concluded that the Russell two-sample method after injection of 99mTc-DTPA is accurate enough for routine clinical use.
Subjects
MeSH terms (MEDLINE)
Substances
Authors and institutions
- Department of Nuclear Medicine, S. Croce General Hospital, Cuneo, Italy.
Cite
APA
Biggi, A., Viglietti, A., Farinelli, M. C., Bonada, C., & Camuzzini, G. (1995). Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid. European Journal of Nuclear Medicine, 22(6), 532-536. https://doi.org/10.1007/bf00817277
Vancouver
Biggi A, Viglietti A, Farinelli MC, Bonada C, Camuzzini G. Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid. European Journal of Nuclear Medicine. 1995;22(6):532-536. doi:10.1007/bf00817277
BibTeX
@article{Biggi1995,
author = {Biggi, A and Viglietti, A and Farinelli, M C and Bonada, C and Camuzzini, G},
title = {Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid},
journal = {European Journal of Nuclear Medicine},
year = {1995},
volume = {22},
number = {6},
pages = {532--536},
doi = {10.1007/bf00817277}
}