EUVIMEDDescoperă EUVIMED
Vergleichsstudie

Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid

A Biggi, A Viglietti, M C Farinelli, C Bonada, G Camuzzini

European Journal of Nuclear Medicine · 1995-06 · 22 (6) · 532-536

DOI: 10.1007/bf00817277 ↗

At a glance

Vergleichsstudie in European Journal of Nuclear Medicine, 1995-06. Written by A Biggi and 4 co-authors. Institution: Department of Nuclear Medicine, S. Croce General Hospital, Cuneo, Italy. Major MEDLINE topics: Chromium Radioisotopes, Edetic Acid, Glomerular Filtration Rate, Technetium Tc 99m Pentetate. Cited 32 times so far (Crossref); 13 references.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Simultaneous measurements of the clearance rate of chromium-51 ethylene diamine tetra-acetic acid (51Cr-EDTA) and technetium-99m diethylene triamine penta-acetic acid (99mTc-DTPA) were performed in 54 patients with a range of function between 9 and 176 ml/min. Using multiple blood samples the two clearance values correlated well (r = 0.97, SEE 8.6 ml/min) and DTPA clearance was higher by 2.9%. For each radiopharmaceutical the plasma clearance rates obtained using multiple blood samples were compared with those obtained with simplified methods, i.e., the 60-180 min two-sample method of Russell and the mono-exponential method with the Brochner-Mortensen correction. For both radiopharmaceuticals the clearance values correlated well with the Russell method (r = 0.99, SEE = 4.1 ml/min for EDTA; r = 0.99, SEE 4.9 ml/min for DTPA) and the mono-exponential method (r = 0.99, SEE 3.6 ml/min for EDTA; r = 0.99, SEE 3.9 ml/min for DTPA). The mean plasma clearance obtained using multiple blood samples did not differ significantly from that obtained with the Russell method, either in patients with a glomerular filtration rate (GFR) or = 30 ml/min. The mean plasma clearance obtained using multiple blood samples differed significantly from that obtained with the mono-exponential method because of the great difference observed in patients with GFR > or = 30 ml/min. It is concluded that the Russell two-sample method after injection of 99mTc-DTPA is accurate enough for routine clinical use.

Subjects

MeSH terms (MEDLINE)

Chromium RadioisotopesEdetic AcidGlomerular Filtration RateTechnetium Tc 99m PentetateFemaleHumansKidneyMaleMiddle Aged

Substances

Chromium RadioisotopesEdetic AcidTechnetium Tc 99m Pentetate

Authors and institutions

  • Department of Nuclear Medicine, S. Croce General Hospital, Cuneo, Italy.

Cite

APA

Biggi, A., Viglietti, A., Farinelli, M. C., Bonada, C., & Camuzzini, G. (1995). Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid. European Journal of Nuclear Medicine, 22(6), 532-536. https://doi.org/10.1007/bf00817277

Vancouver

Biggi A, Viglietti A, Farinelli MC, Bonada C, Camuzzini G. Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid. European Journal of Nuclear Medicine. 1995;22(6):532-536. doi:10.1007/bf00817277

BibTeX
@article{Biggi1995,
  author = {Biggi, A and Viglietti, A and Farinelli, M C and Bonada, C and Camuzzini, G},
  title = {Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid},
  journal = {European Journal of Nuclear Medicine},
  year = {1995},
  volume = {22},
  number = {6},
  pages = {532--536},
  doi = {10.1007/bf00817277}
}
Start for free →