EUVIMEDEUVIMED entdecken
Vergleichsstudie

Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid

A Biggi, A Viglietti, M C Farinelli, C Bonada, G Camuzzini

European Journal of Nuclear Medicine · 1995-06 · 22 (6) · 532-536

DOI: 10.1007/bf00817277 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Journal of Nuclear Medicine, 1995-06. Verfasst von A Biggi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, S. Croce General Hospital, Cuneo, Italy. Hauptthemen laut MEDLINE: Chromium Radioisotopes, Edetic Acid, Glomerular Filtration Rate, Technetium Tc 99m Pentetate. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Simultaneous measurements of the clearance rate of chromium-51 ethylene diamine tetra-acetic acid (51Cr-EDTA) and technetium-99m diethylene triamine penta-acetic acid (99mTc-DTPA) were performed in 54 patients with a range of function between 9 and 176 ml/min. Using multiple blood samples the two clearance values correlated well (r = 0.97, SEE 8.6 ml/min) and DTPA clearance was higher by 2.9%. For each radiopharmaceutical the plasma clearance rates obtained using multiple blood samples were compared with those obtained with simplified methods, i.e., the 60-180 min two-sample method of Russell and the mono-exponential method with the Brochner-Mortensen correction. For both radiopharmaceuticals the clearance values correlated well with the Russell method (r = 0.99, SEE = 4.1 ml/min for EDTA; r = 0.99, SEE 4.9 ml/min for DTPA) and the mono-exponential method (r = 0.99, SEE 3.6 ml/min for EDTA; r = 0.99, SEE 3.9 ml/min for DTPA). The mean plasma clearance obtained using multiple blood samples did not differ significantly from that obtained with the Russell method, either in patients with a glomerular filtration rate (GFR) or = 30 ml/min. The mean plasma clearance obtained using multiple blood samples differed significantly from that obtained with the mono-exponential method because of the great difference observed in patients with GFR > or = 30 ml/min. It is concluded that the Russell two-sample method after injection of 99mTc-DTPA is accurate enough for routine clinical use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chromium RadioisotopesEdetic AcidGlomerular Filtration RateTechnetium Tc 99m PentetateFemaleHumansKidneyMaleMiddle Aged

Substanzen

Chromium RadioisotopesEdetic AcidTechnetium Tc 99m Pentetate

Autor:innen und Institutionen

  • Department of Nuclear Medicine, S. Croce General Hospital, Cuneo, Italy.

Zitieren

APA

Biggi, A., Viglietti, A., Farinelli, M. C., Bonada, C., & Camuzzini, G. (1995). Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid. European Journal of Nuclear Medicine, 22(6), 532-536. https://doi.org/10.1007/bf00817277

Vancouver

Biggi A, Viglietti A, Farinelli MC, Bonada C, Camuzzini G. Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid. European Journal of Nuclear Medicine. 1995;22(6):532-536. doi:10.1007/bf00817277

BibTeX
@article{Biggi1995,
  author = {Biggi, A and Viglietti, A and Farinelli, M C and Bonada, C and Camuzzini, G},
  title = {Estimation of glomerular filtration rate and technetium-99m diethylene triamine penta-acetic acid using chromium-51 ethylene diamine tetra-acetic acid},
  journal = {European Journal of Nuclear Medicine},
  year = {1995},
  volume = {22},
  number = {6},
  pages = {532--536},
  doi = {10.1007/bf00817277}
}