Comparative Evaluation of Different Blood Collection Sites for the Assessment of Beta‐Hydroxybutyric Acid Concentrations Using a Handheld Meter in Sheep
Veterinary Medicine and Science · 2025-09 · 11 (5)
DOI: 10.1002/vms3.70592 ↗At a glance
Vergleichsstudie in Veterinary Medicine and Science, published online on 2025-08-26. Written by Mehmet Akköse and 4 co-authors. Institution: Department of Livestock, Dalaman Agricultural Enterprise, General Directorate of Agricultural Enterprises, Muğla, Türkiye. Major MEDLINE topics: 3-Hydroxybutyric Acid, Blood Specimen Collection. Cited 1 times so far (Crossref); 31 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Hyperketonaemia is a common problem in periparturient sheep. This study aimed to evaluate the performance of FreeStyle Optium Neo H (FS) for measuring blood β‐hydroxybutyric acid (BHBA) concentrations in sheep. Whole‐blood BHBA concentrations were measured using the FS from the jugular and ear veins of 175 clinically healthy, late‐gestation ( n = 56) and postparturient ( n = 119) ewes. Jugular blood serum samples were also used for the reference sampling site. Blood BHBA concentrations measured with the FS from the jugular and ear veins showed a high positive correlation with the serum concentrations measured using the reference method ( r = 0.84, r = 0.81, respectively). According to the Bland–Altman plot and limits of agreement, when compared to the reference method, FS recorded lower BHBA concentrations of 0.03 and 0.04 mmol/L from the jugular and ear veins, respectively. Passing–Bablok regression analysis revealed an intercept of −0.125 (95% CI: −0.148 to −0.078) and a slope of 1.250 (95% CI: 1.111–1.304) for the jugular vein and an intercept of −0.005 (95% CI: −0.089 to −0.018) and a slope of 1.000 (95% CI: 0.909–1.111) for the ear vein. The receiver operating characteristics (ROC) analysis determined that the optimal thresholds of the FS for the jugular and ear veins were, respectively, ≥0.8 mmol/L (sensitivity, 87.5%; specificity, 97.6%, AUC, 0.896) and ≥0.6 mmol/L (sensitivity, 87.5%; specificity, 91.0%, AUC, 0.887) for the identification of sheep with pregnancy toxaemia (PT). In conclusion, although there was constant and proportional errors indicating non‐agreement with the reference method in the Passing–Bablok regression equation, FS's diagnostic performance was good enough to identify ewes with PT or hyperketonaemia.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Livestock, Dalaman Agricultural Enterprise, General Directorate of Agricultural Enterprises, Muğla, Türkiye.
- Department of Biostatistics, Faculty of Veterinary Medicine, Hatay Mustafa Kemal University, Antakya, Türkiye.
- Department of Obstetrics and Gynecology, Faculty of Veterinary Medicine, Ankara University, Ankara, Türkiye.
- Graduate School of Health Sciences, Faculty of Veterinary Medicine, Ankara University, Ankara, Türkiye.
ORCID profiles: Mehmet Akköse, Ufuk Kaya, Murat Onur Yazlik
Cite
APA
Akköse, M., Kaya, U., Yazlik, M. O., Göcen, M., & Vural, M. R. (2025). Comparative Evaluation of Different Blood Collection Sites for the Assessment of Beta‐Hydroxybutyric Acid Concentrations Using a Handheld Meter in Sheep. Veterinary Medicine and Science, 11(5). https://doi.org/10.1002/vms3.70592
Vancouver
Akköse M, Kaya U, Yazlik MO, Göcen M, Vural MR. Comparative Evaluation of Different Blood Collection Sites for the Assessment of Beta‐Hydroxybutyric Acid Concentrations Using a Handheld Meter in Sheep. Veterinary Medicine and Science. 2025;11(5). doi:10.1002/vms3.70592
BibTeX
@article{Akkse2025,
author = {Akköse, Mehmet and Kaya, Ufuk and Yazlik, Murat Onur and Göcen, Murat and Vural, Mehmet Rıfat},
title = {Comparative Evaluation of Different Blood Collection Sites for the Assessment of Beta‐Hydroxybutyric Acid Concentrations Using a Handheld Meter in Sheep},
journal = {Veterinary Medicine and Science},
year = {2025},
volume = {11},
number = {5},
doi = {10.1002/vms3.70592}
}
EUVIMED