EUVIMEDEUVIMED entdecken
Vergleichsstudie

Trimmed central venous catheters do not increase endothelial injury in an ovine model

Hanjay Wang, Kiah M Williams, Stefan Elde iD, Philip L Bulterys, Akshara D Thakore, Haley J Lucian, Justin M Farry, Danielle M Mullis, Yuanjia Zhu, Michael J Paulsen, Y Joseph Woo iD

The Journal of Vascular Access · 2024

DOI: 10.1177/11297298231153716 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, 2024. Verfasst von Hanjay Wang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA. Hauptthemen laut MEDLINE: Central Venous Catheters, Catheterization, Central Venous, Nitric Oxide Synthase Type III, Endothelium, Vascular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: NHLBI NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Central venous catheters (CVCs) are often trimmed during heart transplantation and pediatric cardiac surgery. However, the risk of endothelial injury caused by the cut tip of the CVC has not been evaluated. We hypothesized that there is no difference in the degree of endothelial injury associated with trimmed CVCs versus standard untrimmed CVCs.

Methods

In four adult male sheep, the left external jugular vein was exposed in three segments, one designated for an untouched control group, one for the trimmed CVC group, and one for the untrimmed CVC group. Trimmed and untrimmed CVC tips were rotated circumferentially within their respective segments to abrade the lumen of the vein. The vein samples were explanted, and two representative sections from each sample were analyzed using hematoxylin and eosin (H&E) staining, as well as with immunohistochemistry against CD31, von Willebrand factor (vWF), endothelial nitric oxide synthase (eNOS), and caveolin. Higher immunohistochemical stain distributions and intensities are associated with normal health and function of the venous endothelium. Data are presented as counts with percentages or as means with standard error.

Results

H&E staining revealed no evidence of endothelial injury in 6/8 (75%) samples from the untouched control group, and no injury in 4/8 (50%) samples from both the trimmed and untrimmed CVC groups ( p = 0.504). In all remaining samples from each group, only mild endothelial injury was observed. Immunohistochemical analysis comparing trimmed CVCs versus untrimmed CVCs revealed no difference in the percentage of endothelial cells staining positive for CD31 (57.5% ± 7.2% vs 55.0% ± 9.2%, p = 0.982), vWF (73.8% ± 8.0% vs 62.5% ± 9.6%, p = 0.579), eNOS (66.3% ± 4.2% vs 63.8% ± 7.5%, p = 0.962), and caveolin (53.8% ± 5.0% vs 51.3% ± 4.4%, p = 0.922). There were no significant differences between the groups in the distributions of stain intensity for CD31, vWF, eNOS, and caveolin.

Conclusion

Trimmed CVCs do not increase endothelial injury compared to standard untrimmed CVCs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Central Venous CathetersCatheterization, Central VenousNitric Oxide Synthase Type IIIEndothelium, Vascularvon Willebrand FactorJugular VeinsPlatelet Endothelial Cell Adhesion Molecule-1Vascular System InjuriesSheep, DomesticBiomarkersModels, AnimalAnimalsMaleEquipment DesignEndothelial CellsCaveolin 1

Stichwörter der Autor:innen

Cathetercardiac surgeryendotheliuminjurytrim

Substanzen

Nitric Oxide Synthase Type IIIvon Willebrand FactorPlatelet Endothelial Cell Adhesion Molecule-1BiomarkersCaveolin 1

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
  • Department of Pathology, Stanford University, Stanford, CA, USA.
  • Department of Bioengineering, Stanford University, Stanford, CA, USA.

ORCID-Profile: Stefan Elde, Y Joseph Woo

Förderung

  • NHLBI NIH HHS
  • National Institutes of Health

Zitieren

APA

Wang, H., Williams, K. M., Elde, S., Bulterys, P. L., Thakore, A. D., Lucian, H. J., Farry, J. M., Mullis, D. M., Zhu, Y., Paulsen, M. J., & Woo, Y. J. (2024). Trimmed central venous catheters do not increase endothelial injury in an ovine model. The Journal of Vascular Access. https://doi.org/10.1177/11297298231153716

Vancouver

Wang H, Williams KM, Elde S, Bulterys PL, Thakore AD, Lucian HJ, et al. Trimmed central venous catheters do not increase endothelial injury in an ovine model. The Journal of Vascular Access. 2024. doi:10.1177/11297298231153716

BibTeX
@article{Wang2024,
  author = {Wang, Hanjay and Williams, Kiah M and Elde, Stefan and Bulterys, Philip L and Thakore, Akshara D and Lucian, Haley J and Farry, Justin M and Mullis, Danielle M and Zhu, Yuanjia and Paulsen, Michael J and Woo, Y Joseph},
  title = {Trimmed central venous catheters do not increase endothelial injury in an ovine model},
  journal = {The Journal of Vascular Access},
  year = {2024},
  doi = {10.1177/11297298231153716}
}