EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparative Evaluation of Different Blood Collection Sites for the Assessment of Beta‐Hydroxybutyric Acid Concentrations Using a Handheld Meter in Sheep

Mehmet Akköse iD, Ufuk Kaya iD, Murat Onur Yazlik iD, Murat Göcen, Mehmet Rıfat Vural

Veterinary Medicine and Science · 2025-09 · 11 (5)

DOI: 10.1002/vms3.70592 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Medicine and Science, online erschienen am 26.08.2025. Verfasst von Mehmet Akköse und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Livestock, Dalaman Agricultural Enterprise, General Directorate of Agricultural Enterprises, Muğla, Türkiye. Hauptthemen laut MEDLINE: 3-Hydroxybutyric Acid, Blood Specimen Collection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hyperketonaemia is a common problem in periparturient sheep. This study aimed to evaluate the performance of FreeStyle Optium Neo H (FS) for measuring blood β‐hydroxybutyric acid (BHBA) concentrations in sheep. Whole‐blood BHBA concentrations were measured using the FS from the jugular and ear veins of 175 clinically healthy, late‐gestation ( n = 56) and postparturient ( n = 119) ewes. Jugular blood serum samples were also used for the reference sampling site. Blood BHBA concentrations measured with the FS from the jugular and ear veins showed a high positive correlation with the serum concentrations measured using the reference method ( r = 0.84, r = 0.81, respectively). According to the Bland–Altman plot and limits of agreement, when compared to the reference method, FS recorded lower BHBA concentrations of 0.03 and 0.04 mmol/L from the jugular and ear veins, respectively. Passing–Bablok regression analysis revealed an intercept of −0.125 (95% CI: −0.148 to −0.078) and a slope of 1.250 (95% CI: 1.111–1.304) for the jugular vein and an intercept of −0.005 (95% CI: −0.089 to −0.018) and a slope of 1.000 (95% CI: 0.909–1.111) for the ear vein. The receiver operating characteristics (ROC) analysis determined that the optimal thresholds of the FS for the jugular and ear veins were, respectively, ≥0.8 mmol/L (sensitivity, 87.5%; specificity, 97.6%, AUC, 0.896) and ≥0.6 mmol/L (sensitivity, 87.5%; specificity, 91.0%, AUC, 0.887) for the identification of sheep with pregnancy toxaemia (PT). In conclusion, although there was constant and proportional errors indicating non‐agreement with the reference method in the Passing–Bablok regression equation, FS's diagnostic performance was good enough to identify ewes with PT or hyperketonaemia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

3-Hydroxybutyric AcidBlood Specimen CollectionAnimalsFemaleSheepJugular VeinsSheep, DomesticEar

Stichwörter der Autor:innen

FreeStyle Optium Neo Hewehyperketonaemiaβ‐hydroxybutyric acid

Substanzen

3-Hydroxybutyric Acid

Autor:innen und Institutionen

  • Department of Livestock, Dalaman Agricultural Enterprise, General Directorate of Agricultural Enterprises, Muğla, Türkiye.
  • Department of Biostatistics, Faculty of Veterinary Medicine, Hatay Mustafa Kemal University, Antakya, Türkiye.
  • Department of Obstetrics and Gynecology, Faculty of Veterinary Medicine, Ankara University, Ankara, Türkiye.
  • Graduate School of Health Sciences, Faculty of Veterinary Medicine, Ankara University, Ankara, Türkiye.

ORCID-Profile: Mehmet Akköse, Ufuk Kaya, Murat Onur Yazlik

Zitieren

APA

Akköse, M., Kaya, U., Yazlik, M. O., Göcen, M., & Vural, M. R. (2025). Comparative Evaluation of Different Blood Collection Sites for the Assessment of Beta‐Hydroxybutyric Acid Concentrations Using a Handheld Meter in Sheep. Veterinary Medicine and Science, 11(5). https://doi.org/10.1002/vms3.70592

Vancouver

Akköse M, Kaya U, Yazlik MO, Göcen M, Vural MR. Comparative Evaluation of Different Blood Collection Sites for the Assessment of Beta‐Hydroxybutyric Acid Concentrations Using a Handheld Meter in Sheep. Veterinary Medicine and Science. 2025;11(5). doi:10.1002/vms3.70592

BibTeX
@article{Akkse2025,
  author = {Akköse, Mehmet and Kaya, Ufuk and Yazlik, Murat Onur and Göcen, Murat and Vural, Mehmet Rıfat},
  title = {Comparative Evaluation of Different Blood Collection Sites for the Assessment of Beta‐Hydroxybutyric Acid Concentrations Using a Handheld Meter in Sheep},
  journal = {Veterinary Medicine and Science},
  year = {2025},
  volume = {11},
  number = {5},
  doi = {10.1002/vms3.70592}
}
Kostenlos starten →