A Simple and Rapid Analytical Method to Detect and Quantify the N‐Nitroso Desmethyl Diltiazem Impurity by Liquid Chromatography‐Tandem Mass Spectrometry in Diltiazem Hydrochloride
SEPARATION SCIENCE PLUS · 2025-05 · 8 (5)
DOI: 10.1002/sscp.70065 ↗Kurz gefasst
Fachartikel in der Zeitschrift SEPARATION SCIENCE PLUS, online erschienen am 26.05.2025. Verfasst von Manoj Kumar Mandapaka und 1 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
N‐nitroso desmethyl diltiazem is a known genotoxic impurity in the cardiovascular drug product diltiazem hydrochloride, raising significant concerns due to its potential carcinogenicity. Detection of such impurities at trace levels is crucial to ensure drug safety and regulatory compliance. Thus, an effective and robust analytical method has been developed and validated with improved specificity, sensitivity, and separation efficiency using multiple reaction monitoring acquisition mode to detect and quantify the traces of N‐nitroso desmethyl diltiazem in diltiazem hydrochloride. Achieved an excellent separation and quantification of N‐nitroso desmethyl diltiazem and diltiazem hydrochloride in a short run time of 24 min by using a C18 Atlantis T3 column with a gradient composition of 0.1% formic acid in water as mobile phase A and 100% acetonitrile as mobile phase B, 0.5 mL min −1 flow rate, and a 10 µL injection volume. Mass spectrometric conditions comprised 1.00 kV interface and focus voltage through positive polarity in multiple reaction monitoring mode, with precursor ion at 429.90 m / z and product ion at 283.25 m / z . This method demonstrated excellent specificity, achieving baseline separation of N‐nitroso desmethyl diltiazem from matrix components, and exhibited linearity within a concentration range of 0.0025–0.1 µg mL −1 . Validation parameters, including accuracy, precision, and robustness, are obtained within acceptable limits as per International Council for Harmonization guidelines, ensuring the method's reliability. This study addressed the limitations of previous techniques and underscored the method's potential for routine analysis to meet regulatory compliance requirements.
Zitieren
APA
Mandapaka, M. K., & Boddu, V. (2025). A Simple and Rapid Analytical Method to Detect and Quantify the N‐Nitroso Desmethyl Diltiazem Impurity by Liquid Chromatography‐Tandem Mass Spectrometry in Diltiazem Hydrochloride. SEPARATION SCIENCE PLUS, 8(5). https://doi.org/10.1002/sscp.70065
Vancouver
Mandapaka MK, Boddu V. A Simple and Rapid Analytical Method to Detect and Quantify the N‐Nitroso Desmethyl Diltiazem Impurity by Liquid Chromatography‐Tandem Mass Spectrometry in Diltiazem Hydrochloride. SEPARATION SCIENCE PLUS. 2025;8(5). doi:10.1002/sscp.70065
BibTeX
@article{Mandapaka2025,
author = {Mandapaka, Manoj Kumar and Boddu, Veeraswami},
title = {A Simple and Rapid Analytical Method to Detect and Quantify the N‐Nitroso Desmethyl Diltiazem Impurity by Liquid Chromatography‐Tandem Mass Spectrometry in Diltiazem Hydrochloride},
journal = {SEPARATION SCIENCE PLUS},
year = {2025},
volume = {8},
number = {5},
doi = {10.1002/sscp.70065}
}