Developing, validating, and comparing an analytical method to simultaneously detect z-drugs in urine samples using the QuEChERS approach with both liquid chromatography and gas chromatography-tandem mass spectrometry

Varsha Chauhan, Manu Sharma, Abhishek Tiwari, Varsha Tiwari, Manish Kumar, Ajay Sharma, Arya Lakshmi Marisetti, Ashok Kumar, Abdulsalam Alhalmi, Omar M Noman, Ahmad Alahdab

Saudi Pharmaceutical Journal · 2024-02 · 32 (2) · 101950

DOI: 10.1016/j.jsps.2023.101950 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Saudi Pharmaceutical Journal, 2024-02. Verfasst von Varsha Chauhan und 10 weiteren Autor:innen. Beteiligte Einrichtung: National Forensic Science University, Delhi Campus, Ministry of Home Affairs, Sec-3, Rohini, Delhi 110085, India. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: King Saud University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detecting z-drugs, a sedative-hypnotic medication, is also misused for criminal activities. Therefore, the analysis of urine samples is crucial for clinical and forensic purposes. We conducted a study where we developed, validated, and compared an analytical method for simultaneously detecting z-drugs in urine samples. Our approach uses the QuEChERS method for sample preparation, combined with liquid chromatography (LC) and gas chromatography (GC) coupled with tandem mass spectrometry (MS/MS). We optimized the QuEChERS method to effectively extract z-drugs from urine samples while minimizing matrix effects and achieving high recovery rates. After extraction, we split the samples into two parts for analysis using LC-MS/MS and GC-MS/MS. We validated our methods, and the results showed good linearity over a broad concentration range (1-200 ng/mL) for each z-drug. The limits of detection and quantification were within clinically relevant ranges, ensuring sensitivity for detecting z-drugs in urine samples. We compared the two chromatographic techniques by analyzing a set of urine samples spiked with known concentrations of z-drugs using both LC-MS/MS and GC-MS/MS methods and then applied to the real samples. The results were statistically analyzed to assess any significant differences in accuracy and precision above 95 %, and both methods offered reliable and consistent results with the samples as well. In conclusion, our analytical method coupled with both LC-MS/MS and GC-MS/MS using the QuEChERS approach provides a comprehensive and robust solution for the simultaneous detection of z-drugs in urine samples. The choice between the two chromatographic techniques can be based on the specific z-drugs of interest and the required analytical performance. This method holds promise for applications in clinical toxicology, forensic analysis, and monitoring z-drug usage.

Schlagwörter

Stichwörter der Autor:innen

EszopicloneGC–MS/MSLC−MS/MSQuEChERSZolpidemZopiclone

Autor:innen und Institutionen

  • National Forensic Science University, Delhi Campus, Ministry of Home Affairs, Sec-3, Rohini, Delhi 110085, India.
  • Pharmacy Academy, IFTM University, Lodhipur-Rajput, Moradabad, (U.P.) 244102, India.
  • Department of Pharmaceutics, ISF College of Pharmacy, Moga, Punjab, India.
  • School of Pharmaceutical Sciences, Delhi Pharmaceutical Sciences and Research University, Pushp Vihar, New Delhi 110017, India.
  • School of Pharmacy, Graphic Era Hill University, Dehradun 248002, India.
  • School Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, India.

Förderung

  • King Saud University

Zitieren

APA

Chauhan, V., Sharma, M., Tiwari, A., Tiwari, V., Kumar, M., Sharma, A., Marisetti, A. L., Kumar, A., Alhalmi, A., Noman, O. M., & Alahdab, A. (2024). Developing, validating, and comparing an analytical method to simultaneously detect z-drugs in urine samples using the QuEChERS approach with both liquid chromatography and gas chromatography-tandem mass spectrometry. Saudi Pharmaceutical Journal, 32(2), 101950. https://doi.org/10.1016/j.jsps.2023.101950

Vancouver

Chauhan V, Sharma M, Tiwari A, Tiwari V, Kumar M, Sharma A, et al. Developing, validating, and comparing an analytical method to simultaneously detect z-drugs in urine samples using the QuEChERS approach with both liquid chromatography and gas chromatography-tandem mass spectrometry. Saudi Pharmaceutical Journal. 2024;32(2):101950. doi:10.1016/j.jsps.2023.101950

BibTeX
@article{Chauhan2024,
  author = {Chauhan, Varsha and Sharma, Manu and Tiwari, Abhishek and Tiwari, Varsha and Kumar, Manish and Sharma, Ajay and Marisetti, Arya Lakshmi and Kumar, Ashok and Alhalmi, Abdulsalam and Noman, Omar M and Alahdab, Ahmad},
  title = {Developing, validating, and comparing an analytical method to simultaneously detect z-drugs in urine samples using the QuEChERS approach with both liquid chromatography and gas chromatography-tandem mass spectrometry},
  journal = {Saudi Pharmaceutical Journal},
  year = {2024},
  volume = {32},
  number = {2},
  pages = {101950},
  doi = {10.1016/j.jsps.2023.101950}
}