Analytical determination of ethylenediamine impurity in tripelennamine hydrochloride by gas chromatography–mass spectrometry using phthalaldehyde as the derivatizing agent
Biomedical Chromatography · 2024-06 · 38 (6)
DOI: 10.1002/bmc.5850 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 22.02.2024. Verfasst von Sayyad Kousrali und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Chemistry, Koneru Lakshmaiah Education Foundation, Aziznagar, Hyderabad, Telangana, India. Hauptthemen laut MEDLINE: Gas Chromatography-Mass Spectrometry, Ethylenediamines, o-Phthalaldehyde, Limit of Detection. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Science and Engineering Research Board, Department of Science and Technology, New Delhi, India.
Abstract (Originalsprache)
In the pharmaceutical industry, effective risk management and control strategies for potential genotoxic impurities are of paramount importance. The current study utilized GC–MS to evaluate a precise, linear, and accurate analytical method for quantifying ethylenediamine present in tripelennamine hydrochloride using phthalaldehyde as a derivatizing agent. When phthalaldehyde is sonicated for 10 min at room temperature, it reacts with ethylenediamine to form (1z,5z)‐3,4‐dihydrobenzo[f][1,4]diazocine. This approach minimizes matrix interference issues and resolves sample preparation difficulties encountered during ethylenediamine identification in GC–MS. In this method, helium serves as the carrier gas, while methanol acts as the diluent. The stationary phase consists of a DB‐5MS column (30 m × 0.25 mm × 0.25 μm) with a flow rate of 1.5 mL/min. The retention time of (1z,5z)‐3,4‐dihydrobenzo[f][1,4]diazocine was determined to be 6.215 min. The method validation demonstrated limits of detection and quantification for (1z,5z)‐3,4‐dihydrobenzo[f][1,4]diazocine at 0.4 and 1.0 ppm, respectively, with a linearity range spanning from 1 to 30 ppm concentration with respect to the specification level. System suitability, precision, linearity, and accuracy of the current method were assessed in accordance with guidelines, yielding results deemed suitable for the intended use.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Engineering Chemistry, Koneru Lakshmaiah Education Foundation, Aziznagar, Hyderabad, Telangana, India.
- Analytical Development Department, Shenzhen DEC Pharmaceutical Co., Ltd, Shenzhen, China.
ORCID-Profile: Tanmoy Mondal
Förderung
- Science and Engineering Research Board
- Department of Science and Technology, New Delhi, India
Zitieren
APA
Kousrali, S., Kowtharapu, L. P., & Mondal, T. (2024). Analytical determination of ethylenediamine impurity in tripelennamine hydrochloride by gas chromatography–mass spectrometry using phthalaldehyde as the derivatizing agent. Biomedical Chromatography, 38(6). https://doi.org/10.1002/bmc.5850
Vancouver
Kousrali S, Kowtharapu LP, Mondal T. Analytical determination of ethylenediamine impurity in tripelennamine hydrochloride by gas chromatography–mass spectrometry using phthalaldehyde as the derivatizing agent. Biomedical Chromatography. 2024;38(6). doi:10.1002/bmc.5850
BibTeX
@article{Kousrali2024,
author = {Kousrali, Sayyad and Kowtharapu, Leela Prasad and Mondal, Tanmoy},
title = {Analytical determination of ethylenediamine impurity in tripelennamine hydrochloride by gas chromatography–mass spectrometry using phthalaldehyde as the derivatizing agent},
journal = {Biomedical Chromatography},
year = {2024},
volume = {38},
number = {6},
doi = {10.1002/bmc.5850}
}
EUVIMED