Flexible Microneedle Array Electrode with Improved Comfort, Low Impedance, and High Performance for Electrophysiological Recording
Small · 2026
DOI: 10.1002/smll.75417 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small, 2026. Verfasst von Heping Wu und 12 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory for Manufacturing Systems Engineering, Electronic Materials Research Laboratory, Key Laboratory of the Ministry of Education, Sc…. Hauptthemen laut MEDLINE: Needles, Electrophysiology, Electrophysiological Phenomena. Die Arbeit nennt 68 Literaturangaben.
Abstract (Originalsprache)
High‐fidelity electrophysiological recording is critical for wearable brain–computer interfaces and human–machine interaction. However, balancing signal quality and wearing comfort remains a challenge: wet electrodes suffer from gel dehydration, whereas conventional dry electrodes often exhibit high impedance and mechanical instability. Here, we present a flexible microneedle array (fMNA) electrode fabricated using a scalable micro‐electro‐mechanical system process. The electrode comprises octagonal pyramidal silicon microneedles coated with Au/Cr on a flexible parylene substrate, providing high conductivity, mechanical robustness, and conformal scalp contact. Integrated with a specialized denoising algorithm, the fMNA achieved a contact impedance of 7.6 kΩ@10 Hz, 1–2 orders of magnitude lower than that of commercial wet electrodes. It also exhibited excellent durability and flexibility, with a minimum bending radius of 3 mm. Its recording performance was systematically validated through electroencephalographic visual evoked potential and cognitive engagement experiments, together with electrooculography. Compared with wet electrodes, the fMNA produced 41%–46% higher signal amplitudes, a higher signal‐to‐noise ratio, improved stability, lower impedance drift, and fewer motion artifacts. These results establish the fMNA as a versatile platform for high‐quality electrophysiological recording and long‐term wearable bioelectronic monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory for Manufacturing Systems Engineering, Electronic Materials Research Laboratory, Key Laboratory of the Ministry of Education, School of Electronic Science and Engineering, Xi'an Jiaotong University,…
- Zhuzhou CRRC Times Semiconductor Co. Ltd., Zhuzhou, China.
- School of Microelectronics, Xidian University, Xi'an, China.
- School of Instrument Science and Technology, Xi'an Jiaotong University, Xi'an, China.
- The State Key Laboratory for Manufacturing Systems Engineering & The International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technology, Xi'an Jiaotong University, Xi'an, China.
ORCID-Profile: Heping Wu, Zhikang Li, Libo Zhao, Gang Niu
Zitieren
APA
Wu, H., Yang, Y., Liu, C., Ge, Y., Zhang, J., Wang, B., Ren, X., An, R., Quan, Y., Li, Z., Zhao, L., Ren, W., & Niu, G. (2026). Flexible Microneedle Array Electrode with Improved Comfort, Low Impedance, and High Performance for Electrophysiological Recording. Small. https://doi.org/10.1002/smll.75417
Vancouver
Wu H, Yang Y, Liu C, Ge Y, Zhang J, Wang B, et al. Flexible Microneedle Array Electrode with Improved Comfort, Low Impedance, and High Performance for Electrophysiological Recording. Small. 2026. doi:10.1002/smll.75417
BibTeX
@article{Wu2026,
author = {Wu, Heping and Yang, Yiming and Liu, Chunmei and Ge, Yi and Zhang, Jie and Wang, Baichuan and Ren, Xin and An, Ruihua and Quan, Yi and Li, Zhikang and Zhao, Libo and Ren, Wei and Niu, Gang},
title = {Flexible Microneedle Array Electrode with Improved Comfort, Low Impedance, and High Performance for Electrophysiological Recording},
journal = {Small},
year = {2026},
doi = {10.1002/smll.75417}
}
EUVIMED