Fachartikel in der Zeitschrift Small, online erschienen am 05.05.2023. Verfasst von Alessandro Silvestri und 8 weiteren Autor:innen. Beteiligte Einrichtung: Center for Cooperative Research in Biomaterials (CIC BiomaGUNE), Basque Research and Technology Alliance (BRTA), Donostia-San Sebastián, 20014, Spain. Hauptthemen laut MEDLINE: Graphite, Nanostructures, Biosensing Techniques. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Juan de la Cierva Formacion, MCIN/AEI, the Agencia Estatal de Investigación.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hundreds of new electrochemical sensors are reported in literature every year. However, only a few of them makes it to the market. Manufacturability, or rather the lack of it, is the parameter that dictates if new sensing technologies will remain forever in the laboratory in which they are conceived. Inkjet printing is a low‐cost and versatile technique that can facilitate the transfer of nanomaterial‐based sensors to the market. Herein, an electroactive and self‐assembling inkjet‐printable ink based on protein‐nanomaterial composites and exfoliated graphene is reported. The consensus tetratricopeptide proteins (CTPRs), used to formulate this ink, are engineered to template and coordinate electroactive metallic nanoclusters (NCs), and to self‐assemble upon drying, forming stable films. The authors demonstrate that, by incorporating graphene in the ink formulation, it is possible to dramatically improve the electrocatalytic properties of the ink, obtaining an efficient hybrid material for hydrogen peroxide (H 2 O 2 ) detection. Using this bio‐ink, the authors manufactured disposable and environmentally sustainable electrochemical paper‐based analytical devices (ePADs) to detect H 2 O 2 , outperforming commercial screen‐printed platforms. Furthermore, it is demonstrated that oxidoreductase enzymes can be included in the formulation, to fully inkjet‐print enzymatic amperometric biosensors ready to use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteNanostructuresBiosensing TechniquesInk

Stichwörter der Autor:innen

biosensorselectrocatalysiselectrochemical paper-based analytical devicesengineered proteinsgrapheneinkjet printingwater-based inks

Substanzen

Graphite

Autor:innen und Institutionen

  • Center for Cooperative Research in Biomaterials (CIC BiomaGUNE), Basque Research and Technology Alliance (BRTA), Donostia-San Sebastián, 20014, Spain.
  • Department of Chemical and Pharmaceutical Sciences, Universitá Degli Studi di Trieste, Trieste, 34127, Italy.
  • Department of Chemical and Geological Sciences, University of Modena and Reggio Emilia, Modena, 41125, Italy.
  • POLYMAT and Applied Chemistry Department, Faculty of Chemistry, University of the Basque Country UPV/EHU, Donostia-San Sebastián, 20018, Spain.
  • Department of molecular sciences and nanosystems, Ca' Foscari University of Venice, Venezia, 30170, Italy.
  • Institute of Organic Synthesis and Photoreactivity, National Research Council of Italy, Bologna, 40129, Italy.

ORCID-Profile: Maurizio Prato

Förderung

  • Juan de la Cierva Formacion
  • MCIN/AEI
  • the Agencia Estatal de Investigación
  • Agencia Estatal de
  • European Union NextGenerationEU/PRTR
  • European Union's Horizon 2020 Research and Innovation Programme
  • Maria de Maeztu Units of Excellence Program
  • the Spanish State Research Agency

Zitieren

APA

Silvestri, A., Vázquez-Díaz, S., Misia, G., Poletti, F., López-Domene, R., Pavlov, V., Zanardi, C., Cortajarena, A. L., & Prato, M. (2023). An Electroactive and Self‐Assembling Bio‐Ink, based on Protein‐Stabilized Nanoclusters and Graphene, for the Manufacture of Fully Inkjet‐Printed Paper‐Based Analytical Devices. Small, 19(51). https://doi.org/10.1002/smll.202300163

Vancouver

Silvestri A, Vázquez-Díaz S, Misia G, Poletti F, López-Domene R, Pavlov V, et al. An Electroactive and Self‐Assembling Bio‐Ink, based on Protein‐Stabilized Nanoclusters and Graphene, for the Manufacture of Fully Inkjet‐Printed Paper‐Based Analytical Devices. Small. 2023;19(51). doi:10.1002/smll.202300163

BibTeX
@article{Silvestri2023,
  author = {Silvestri, Alessandro and Vázquez-Díaz, Silvia and Misia, Giuseppe and Poletti, Fabrizio and López-Domene, Rocío and Pavlov, Valeri and Zanardi, Chiara and Cortajarena, Aitziber L and Prato, Maurizio},
  title = {An Electroactive and Self‐Assembling Bio‐Ink, based on Protein‐Stabilized Nanoclusters and Graphene, for the Manufacture of Fully Inkjet‐Printed Paper‐Based Analytical Devices},
  journal = {Small},
  year = {2023},
  volume = {19},
  number = {51},
  doi = {10.1002/smll.202300163}
}
Kostenlos starten →