Diagnostic Accuracy of Cough Frequency Monitors: A Systematic Review and Meta‐Analysis
Respirology · 2026-05 · 31 (5) · 459-470
DOI: 10.1002/resp.70229 ↗At a glance
Systematische Übersicht in Respirology, published online on 2026-03-08. Written by Ana Lara Castro Rodrigues and 7 co-authors. Institution: Graduate Program in Rehabilitation and Functional Performance, Ribeirão Preto Medical School (FMRP-USP), University of São Paulo, São Paulo, Brazil. Major MEDLINE topics: Cough. Cited 1 times so far (Crossref); 49 references. The full text is freely available (open access, CC BY 4.0). Funded by: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Fundação de Amparo à Pesquisa do Estado de São Paulo, Fundação de Apoio ao Ensino, Pesquisa e Assistência do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo.
Abstract (original language)
Background and Objective International guidelines emphasise the importance of objective cough assessment for evaluating therapeutic efficacy. Cough negatively impacts quality of life and generates high costs for healthcare systems. However, the accuracy of cough frequency monitors remains unclear. This study aimed to identify tools developed to monitor cough frequency and evaluate their accuracy.
Methods
Observational studies involving adults, children, or infants who used cough frequency monitors were included from the Pubmed/MEDLINE, EMBASE, and Web of Science databases published up to 24 November 2024. Two independent reviewers performed the screening, data extraction, and quality assessment of the studies using QUADAS‐2. Summary estimates of diagnostic accuracy were calculated with meta‐analysis using bivariate mixed effects regression.
Results
Nineteen studies were included in the review. In the 16 studies included in the meta‐analysis with 52,612 events, sensitivity was 89% (95% CI 0.84–0.93, I 2 89.3%) and specificity was 99% (95% CI 0.98–1.00, I 2 88.2%). The area under the curve (AUC) of 0.96 indicated excellent discriminative capacity. In the 11 devices and 4 applications identified, individual accuracy was > 0.9.
Conclusion
The tools are accurate in distinguishing between cough and non‐cough sounds, but their clinical application still presents technical challenges and requires investment. Future research should improve the monitors, maintaining high accuracy but allowing for agile, cost‐effective assessment.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Graduate Program in Rehabilitation and Functional Performance, Ribeirão Preto Medical School (FMRP-USP), University of São Paulo, São Paulo, Brazil.
- Hospital das Clinicas of the Medicine School in Ribeirão Preto, University of São Paulo, São Paulo, Brazil.
- Graduate Program in Biotechnology (PPGBIOTEC), Federal University of Tocantins (UFT), Tocantins, Brazil.
- Applied Statistics and Biometrics. Graduate Program in Biotechnology (PPGBIOTEC), Federal University of Tocantins (UFT), Tocantins, Brazil.
- Department of Health-Medicine and Physiotherapy, University of Gurupi, Tocantins, Brazil.
- Respiratory Physiotherapy School of Life Course & Population Sciences, Faculty of Life Sciences & Medicine, King's College London, London, UK.
ORCID profiles: Ana Lara Castro Rodrigues, Larisse Sousa Reis Passafaro, Daniele Oliveira Dos Santos, Marcos Gontijo da Silva, Noé Mitterhofer Eiterer Ponce de Leon da Costa, Janne Marques Silveira, Arietta Spinou, Ada Clarice Gastaldi
Funding
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Fundação de Amparo à Pesquisa do Estado de São Paulo
- Fundação de Apoio ao Ensino, Pesquisa e Assistência do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo
- Fundação de Apoio ao Ensino, Pesquisa e Assistência
Cite
APA
Rodrigues, A. L. C., Passafaro, L. S. R., Dos Santos, D. O., da Silva, M. G., de Leon da Costa, N. M. E. P., Silveira, J. M., Spinou, A., & Gastaldi, A. C. (2026). Diagnostic Accuracy of Cough Frequency Monitors: A Systematic Review and Meta‐Analysis. Respirology, 31(5), 459-470. https://doi.org/10.1002/resp.70229
Vancouver
Rodrigues ALC, Passafaro LSR, Dos Santos DO, da Silva MG, de Leon da Costa NMEP, Silveira JM, et al. Diagnostic Accuracy of Cough Frequency Monitors: A Systematic Review and Meta‐Analysis. Respirology. 2026;31(5):459-470. doi:10.1002/resp.70229
BibTeX
@article{Rodrigues2026,
author = {Rodrigues, Ana Lara Castro and Passafaro, Larisse Sousa Reis and Dos Santos, Daniele Oliveira and da Silva, Marcos Gontijo and de Leon da Costa, Noé Mitterhofer Eiterer Ponce and Silveira, Janne Marques and Spinou, Arietta and Gastaldi, Ada Clarice},
title = {Diagnostic Accuracy of Cough Frequency Monitors: A Systematic Review and Meta‐Analysis},
journal = {Respirology},
year = {2026},
volume = {31},
number = {5},
pages = {459--470},
doi = {10.1002/resp.70229}
}
EUVIMED