Potential Pneumoconiosis Patients Monitoring and Warning System with Acoustic Signal
Sensors · 2025
DOI: 10.3390/s25061874 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Zhongxu Bao und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mines, Anhui University of Science and Technology, Huainan 2…. Hauptthemen laut MEDLINE: Pneumoconiosis, Acoustics. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Jiangsu Province, the State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mines Open Fund, State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mines Open Fund.
Abstract (Originalsprache)
Monitoring for early symptoms is a critical step in preventing pneumoconiosis. The early signs of pneumoconiosis can be characterized by dyspnea, tachypnea, and cough. While traditional sensor-based methods are promising, they necessitate the wearing of devices and confine human physical movements. On the other hand, camera-based methods have issues related to illumination, obstruction, and privacy. Recently, wireless sensing has attracted a significant amount of research attention. Among wireless signals, acoustic signals possess unique advantages for fine-grained sensing due to their low propagation speed in the air and low hardware requirement. In this paper, we propose a system called P3Warning to realize low-cost warnings for potential pneumoconiosis patients in a contactless manner. For the first time, the designed system utilizes the inaudible acoustic signal to monitor early symptoms of pneumoconiosis (i.e., abnormal respiration and cough), leveraging a pair of commercial speaker and microphone. We introduce and address unique technical challenges, such as formulating a delay elimination method to synchronize transceiver signals and providing a search-based strategy to amplify signal variation for accurate and long-distance vital sign sensing. Ultimately, we apply an innovative signal decomposition technique to reconstruct the respiration waveform and extract features for cough detection. Comprehensive experiments were conducted to evaluate P3Warning. Experiment results show that it can achieve a robust performance with a median error of 0.39 bpm for abnormal respiration pattern monitoring and an accuracy of 95% for cough detection in total, and support the furthest sensing range of up to 4 m.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mines, Anhui University of Science and Technology, Huainan 232000, China.
- School of Computer Science and Technology, China University of Mining and Technology, Xuzhou 221116, China.
ORCID-Profile: Xuehan Zhang, Yuqing Yin, Xu Yang
Förderung
- Natural Science Foundation of Jiangsu Province
- the State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mines Open Fund
- State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mines Open Fund
Zitieren
APA
Bao, Z., Xu, B., Zhang, X., Yin, Y., Yang, X., & Niu, Q. (2025). Potential Pneumoconiosis Patients Monitoring and Warning System with Acoustic Signal. Sensors. https://doi.org/10.3390/s25061874
Vancouver
Bao Z, Xu B, Zhang X, Yin Y, Yang X, Niu Q. Potential Pneumoconiosis Patients Monitoring and Warning System with Acoustic Signal. Sensors. 2025. doi:10.3390/s25061874
BibTeX
@article{Bao2025,
author = {Bao, Zhongxu and Xu, Baoxuan and Zhang, Xuehan and Yin, Yuqing and Yang, Xu and Niu, Qiang},
title = {Potential Pneumoconiosis Patients Monitoring and Warning System with Acoustic Signal},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25061874}
}
EUVIMED