EUVIMEDEUVIMED entdecken
Crossref

Stiffness Optimisation and Kinematics Modelling of a Cable‐Stayed Flexible Manipulator for Endoscopic Surgery

Yanqiang Lei, Fuxin Du, Wenbo Zheng, Liping Zhang iD

The International Journal of Medical Robotics and Computer Assisted Surgery · 2026-02 · 22 (1)

DOI: 10.1002/rcs.70134 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, online erschienen am 11.01.2026. Verfasst von Yanqiang Lei und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation and Electrical Engineering, Linyi University, Linyi, Shandong, China. Hauptthemen laut MEDLINE: Endoscopy, Robotic Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Key Technology Research and Development Program of Shandong Province, Linyi University High-Level Talent Research Startup Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cable‐driven continuum robots face an inherent trade‐off between stiffness and flexibility, with stiffness enhancement representing a critical challenge in the field.

Methods

This study presents a stiffness‐optimised cable‐stayed notched manipulator (CSNM). The Bernoulli–Euler beam theory models elastic beam (EB) deformation for stiffness optimisation, while a simplified piecewise constant‐curvature assumption based on tendon lengths is used for kinematics. An evolution‐based EB optimisation algorithm achieves uniform stress distribution and enhanced load capacity.

Results

Experiments show that the maximum variance of the EB bending angle after optimisation is 0.5°. The maximum motion error of the manipulator on the x ‐axis and y ‐axis is 0.21 and 0.32 mm, respectively. Benefitting from the uniform distribution of stress, the load capacity of the manipulator increases by 100% after optimisation.

Conclusion

These results validate the structural optimisation and kinematic modelling, highlighting the CSNM's potential for endoscopic applications needing flexibility and high load capacity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EndoscopyRobotic Surgical ProceduresBiomechanical PhenomenaAlgorithmsEquipment DesignHumansMotionElasticityStress, MechanicalRoboticsTendonsModels, TheoreticalComputer Simulation

Stichwörter der Autor:innen

endoscopic surgerykinematics modellingmedical robotnotched manipulatorstiffness optimisation

Autor:innen und Institutionen

  • School of Automation and Electrical Engineering, Linyi University, Linyi, Shandong, China.
  • School of Mechanical Engineering, Shandong University, Jinan, Shandong, China.
  • MH Robot & Automation Co., Ltd., Zhucheng, Shandong, China.
  • School of Logistics, Linyi University, Linyi, Shandong, China.

ORCID-Profile: Liping Zhang

Förderung

  • Key Technology Research and Development Program of Shandong Province
  • Linyi University High-Level Talent Research Startup Fund

Zitieren

APA

Lei, Y., Du, F., Zheng, W., & Zhang, L. (2026). Stiffness Optimisation and Kinematics Modelling of a Cable‐Stayed Flexible Manipulator for Endoscopic Surgery. The International Journal of Medical Robotics and Computer Assisted Surgery, 22(1). https://doi.org/10.1002/rcs.70134

Vancouver

Lei Y, Du F, Zheng W, Zhang L. Stiffness Optimisation and Kinematics Modelling of a Cable‐Stayed Flexible Manipulator for Endoscopic Surgery. The International Journal of Medical Robotics and Computer Assisted Surgery. 2026;22(1). doi:10.1002/rcs.70134

BibTeX
@article{Lei2026,
  author = {Lei, Yanqiang and Du, Fuxin and Zheng, Wenbo and Zhang, Liping},
  title = {Stiffness Optimisation and Kinematics Modelling of a Cable‐Stayed Flexible Manipulator for Endoscopic Surgery},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2026},
  volume = {22},
  number = {1},
  doi = {10.1002/rcs.70134}
}