EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Increasing Reachability in Robotic Ultrasound Through Base Placement and Tool Design

Jonas Osburg iD, Ngoc Thinh Nguyen, Floris Ernst iD

The International Journal of Medical Robotics and Computer Assisted Surgery · 2025

DOI: 10.1002/rcs.70037 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Jonas Osburg und 2 weiteren Autor:innen. Beteiligte Einrichtung: Insitute for Robotics and Kognitive Systems, University of Luebeck, Luebeck, Germany. Hauptthemen laut MEDLINE: Equipment Design, Ultrasonography, Robotic Surgical Procedures. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Robotic ultrasound visualises internal organs in real‐time for various medical applications without the harm of X‐rays. The ultrasound probe is attached to the robot's end effector using custom‐developed probe holders. This paper analyzes the impact of different probe holder geometries on the robot's base placement and reachability.

Methods

We propose a method to improve probe holder geometries and robot base placements to enhance reachability, validated using a 7‐DoF serial manipulator (KUKA iiwa 7) for ultrasound scans of multiple subcutaneous body parts.

Results

Without additional space restrictions, the number of robot base positions with high reachability could be strongly increased with an improved probe holder geometry. Under space constraints, previously unreachable target poses became accessible by adapting the probe holder geometry.

Conclusions

Our method provides an automated solution for determining improved probe holder geometries, enhancing reachability to target areas, especially when the robot's placing area is limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Equipment DesignUltrasonographyRobotic Surgical ProceduresHumansRoboticsPhantoms, ImagingReproducibility of Results

Stichwörter der Autor:innen

reachabilityrobot base placementrobotic ultrasoundtool geometryultrasound liver examination

Autor:innen und Institutionen

  • Insitute for Robotics and Kognitive Systems, University of Luebeck, Luebeck, Germany.

ORCID-Profile: Jonas Osburg, Floris Ernst

Förderung

  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Osburg, J., Nguyen, N. T., & Ernst, F. (2025). Increasing Reachability in Robotic Ultrasound Through Base Placement and Tool Design. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70037

Vancouver

Osburg J, Nguyen NT, Ernst F. Increasing Reachability in Robotic Ultrasound Through Base Placement and Tool Design. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70037

BibTeX
@article{Osburg2025,
  author = {Osburg, Jonas and Nguyen, Ngoc Thinh and Ernst, Floris},
  title = {Increasing Reachability in Robotic Ultrasound Through Base Placement and Tool Design},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70037}
}