EUVIMEDEUVIMED entdecken
Validierungsstudie

Efficient and Simultaneous LC‐MS/MS Detection of N‐Nitroso and Di‐Nitroso Leucovorin in Leucovorin Drug Products: Method Development and Validation

Jaya Yalamanchili, Himavathi Ganja, Suresh Salakolusu iD

Rapid Communications in Mass Spectrometry · 30.05.2026 · 40 (10)

DOI: 10.1002/rcm.70049 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 10.03.2026. Verfasst von Jaya Yalamanchili und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, GITAM School of Science, GITAM Deemed to be University, Vishakhapatnam, Andhra Pradesh, India. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Leucovorin, Nitroso Compounds. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

The occurrence of complex nitrosamines, namely, N‐nitroso drug substance related impurities (NDRSI) in pharmaceuticals is of great concern due to their potential carcinogenic and mutagenic properties. This creates the need for more rigid and more specific methods of analysis to determine NDSRI levels in pharmaceutical products. The main analysis problem is that it is difficult to separate these impurities and the active pharmaceutical ingredient by chromatography, which is due to their structural similarity. This study describes how a new method of measuring two specific impurities in the Leucovorin drug product, N‐nitroso leucovorin and di‐nitroso leucovorin, was developed and validated.

Methods

Quantification was done by selective reaction monitoring by a positive electrospray ionization source. The required separation was achieved with the use of a reverse‐phase C‐8 column and gradient‐elution in the methanol and water solutions, both adjusted with 0.1% formic acid.

Results

Linearity of the method was established in a range of 0.1 to 1.5 ng/mL, which is effectually 10% to 150% of its necessary regulatory limit. The procedure had a detection limit of 0.05 ng/mL and a quantitation limit of 0.1 ng/mL. Additionally, it also demonstrated excellent specificity, precision, linearity, accuracy, and robustness when dealing with the two impurities.

Conclusions

This methodology will therefore offer a crucial solution to drug manufacturers to track and control N‐nitroso leucovorin and Di‐nitroso leucovorin concentrations, which will have a positive impact on regulatory compliance and patient safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryLeucovorinNitroso CompoundsReproducibility of ResultsDrug ContaminationLimit of DetectionLinear Models

Stichwörter der Autor:innen

leucovorinliquid chromatography–tandem mass spectrometer (LC‐MS/MS)nitroso drug substance related impurities (NDSRIs)selective reaction monitoring (SRM)

Substanzen

LeucovorinNitroso Compounds

Autor:innen und Institutionen

  • Department of Chemistry, GITAM School of Science, GITAM Deemed to be University, Vishakhapatnam, Andhra Pradesh, India.
  • Analytical Discovery Chemistry, Aragen Life Sciences Pvt. Ltd., Hyderabad, India.

ORCID-Profile: Suresh Salakolusu

Zitieren

APA

Yalamanchili, J., Ganja, H., & Salakolusu, S. (2026). Efficient and Simultaneous LC‐MS/MS Detection of N‐Nitroso and Di‐Nitroso Leucovorin in Leucovorin Drug Products: Method Development and Validation. Rapid Communications in Mass Spectrometry, 40(10). https://doi.org/10.1002/rcm.70049

Vancouver

Yalamanchili J, Ganja H, Salakolusu S. Efficient and Simultaneous LC‐MS/MS Detection of N‐Nitroso and Di‐Nitroso Leucovorin in Leucovorin Drug Products: Method Development and Validation. Rapid Communications in Mass Spectrometry. 2026;40(10). doi:10.1002/rcm.70049

BibTeX
@article{Yalamanchili2026,
  author = {Yalamanchili, Jaya and Ganja, Himavathi and Salakolusu, Suresh},
  title = {Efficient and Simultaneous LC‐MS/MS Detection of N‐Nitroso and Di‐Nitroso Leucovorin in Leucovorin Drug Products: Method Development and Validation},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2026},
  volume = {40},
  number = {10},
  doi = {10.1002/rcm.70049}
}
Kostenlos starten →