Comparative analysis of impurity profiles in rifampicin capsules with different crystal forms using LC-MS/MS

Yun Shen, Jinlin Zhang, Qian Zhang, Wen-Qian Liu, Si-Tong Zheng, Sheng Tang, Yaozuo Yuan, Hian Kee Lee, Hai-Wei Shi

Journal of Chromatography A · 2025

DOI: 10.1016/j.chroma.2025.465769 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Chromatography A, 2025. Verfasst von Yun Shen und 8 weiteren Autor:innen. Beteiligte Einrichtung: NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing 210019, PR China; China Pharmaceutic…. Hauptthemen laut MEDLINE: Rifampin, Tandem Mass Spectrometry, Drug Contamination. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rifampicin (RIF) is a kind of semi-synthetic antibiotic with broad-spectrum antibacterial action, which has remarkable antibacterial activity against many pathogenic microorganisms. The World Health Organization classifies RIF as critically important for human medicine, especially for tuberculosis treatment. The polymorphic nature of RIF contributes to the complexity of the impurities of the drug. Lack of systematic and comparative studies on its impurities in different crystal forms may affect the efficiency of this drug and increase the incidence of adverse reactions. Current methods in pharmacopoeias and literature can only separate a limited number of known impurities, and the process of preparing the mobile phase is highly cumbersome. In this work, response surface methodology was employed to optimize the conditions of one-dimensional liquid chromatography (LC) as an alternative approach to pharmacopoeia methods. This method demonstrated high accuracy and sensitivity, enabling the quantification of impurities as low as 0.25 μg/mL. The proposed method provided satisfactory linearity, percentage of recovery from 88 to 101 % with relative standard, deviations (RSD) lower than 5 %, indicating good precision. Additionally, the parallel determination of 6 sample solutions showed that the content changes of the relevant components were within an acceptable range, demonstrating method repeatability. A detection method based on high-resolution two-dimensional LC-mass spectrometry (2D-LC-MS/MS) was developed to analyze. A total of 25 impurities were identified and the impurity profiles were systematically investigated for the first time, providing experimental basis for the quality control of the drug.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RifampinTandem Mass SpectrometryDrug ContaminationChromatography, LiquidReproducibility of ResultsCapsulesLinear ModelsLimit of DetectionCrystallizationLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

2D-LC-MS/MSCrystal formImpurityResponse surface methodologyRifampicin

Substanzen

RifampinCapsules

Autor:innen und Institutionen

  • NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing 210019, PR China; China Pharmaceutical University, Nanjing 211121, PR China.
  • NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing 210019, PR China.
  • School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, Jiangsu Province, PR China.
  • NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing 210019, PR China. Electronic address: yyzyz7256@sina.com.
  • School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, Jiangsu Province, PR China; Department of Chemistry, National University of Singapore, 3 Science Drive 3,…
  • NMPA Key Laboratory for Impurity Profile of Chemical Drugs, Jiangsu Institute for Food and Drug Control, Nanjing 210019, PR China. Electronic address: shihaiwei@jsifdc.org.cn.

Zitieren

APA

Shen, Y., Zhang, J., Zhang, Q., Liu, W. Q., Zheng, S. T., Tang, S., Yuan, Y., Lee, H. K., & Shi, H. W. (2025). Comparative analysis of impurity profiles in rifampicin capsules with different crystal forms using LC-MS/MS. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2025.465769

Vancouver

Shen Y, Zhang J, Zhang Q, Liu WQ, Zheng ST, Tang S, et al. Comparative analysis of impurity profiles in rifampicin capsules with different crystal forms using LC-MS/MS. Journal of Chromatography A. 2025. doi:10.1016/j.chroma.2025.465769

BibTeX
@article{Shen2025,
  author = {Shen, Yun and Zhang, Jinlin and Zhang, Qian and Liu, Wen-Qian and Zheng, Si-Tong and Tang, Sheng and Yuan, Yaozuo and Lee, Hian Kee and Shi, Hai-Wei},
  title = {Comparative analysis of impurity profiles in rifampicin capsules with different crystal forms using LC-MS/MS},
  journal = {Journal of Chromatography A},
  year = {2025},
  doi = {10.1016/j.chroma.2025.465769}
}
Kostenlos starten →