EUVIMEDEUVIMED entdecken
Crossref

Development of an UPLC‐MS/MS approach to detect and quantify N‐nitroso mirabegron in mirabegron

Ravi Uppala, Rakesh Chandrakant Prabhu iD, Arthanareeswari Maruthapillai iD, Bandaru Venkatasubbaiah, Gopal Chandru Senadi iD, Sundaramurthy Devikala iD

Rapid Communications in Mass Spectrometry · 2024

DOI: 10.1002/rcm.9911 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2024. Verfasst von Ravi Uppala und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Engineering and Technology, SRM Institute of Science and Technology, India. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Acetanilides, Thiazoles. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the mirabegron (MIR) synthesis, the N‐nitroso mirabegron (NNM) is obtained during synthetic process of MIR; water is being used in reaction under acidic condition. Nitrite source is from water, and secondary amine source is from MIR as it has secondary amine; NNM is generated as an impurity during the synthesis of MIR. The presence of NNM in MIR could potentially affect its effectiveness. The purpose of this study was to establish a Ultra‐performance liquid chromatography‐mass spectrometry/mass spectrometry (UPLC‐MS/MS) methodology to identify NNM in MIR samples. The method for NNM analysis was developed on Acquity HSS T3 (100*2.1) mm 1.8 μm column with gradient elution using mobile phase consisted of 0.1% formic acid in water (mobile phase A) and 0.1% formic acid in methanol (mobile phase B). Mass spectrometer with electrospray ionization operated in the MRM mode was used in the analysis of NNM (m/ z 426.20 → 170.00). The UPLC‐MS/MS methodology proposed showed a good linearity (0.02 to 0.72 ppm), good system precision (RSD = 0.57%), good method precision (RSD = 0.87%), acceptable accuracy (94.5–116.5%), low detection limit (0.006 ppm) and low quantification limit (0.02 ppm) for NNM. The UPLC‐MS/MS methodology proposed can be utilized to assess the quality of MIR sample for the presence of NNM impurity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryAcetanilidesThiazolesChromatography, High Pressure LiquidReproducibility of ResultsLimit of DetectionLinear ModelsDrug ContaminationNitroso CompoundsLiquid Chromatography-Mass Spectrometry

Substanzen

AcetanilidesmirabegronThiazolesNitroso Compounds

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Engineering and Technology, SRM Institute of Science and Technology, India.
  • Dr. Reddys IPDO, Hyderabad, India.

ORCID-Profile: Rakesh Chandrakant Prabhu, Arthanareeswari Maruthapillai, Gopal Chandru Senadi, Sundaramurthy Devikala

Zitieren

APA

Uppala, R., Prabhu, R. C., Maruthapillai, A., Venkatasubbaiah, B., Senadi, G. C., & Devikala, S. (2024). Development of an UPLC‐MS/MS approach to detect and quantify N‐nitroso mirabegron in mirabegron. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9911

Vancouver

Uppala R, Prabhu RC, Maruthapillai A, Venkatasubbaiah B, Senadi GC, Devikala S. Development of an UPLC‐MS/MS approach to detect and quantify N‐nitroso mirabegron in mirabegron. Rapid Communications in Mass Spectrometry. 2024. doi:10.1002/rcm.9911

BibTeX
@article{Uppala2024,
  author = {Uppala, Ravi and Prabhu, Rakesh Chandrakant and Maruthapillai, Arthanareeswari and Venkatasubbaiah, Bandaru and Senadi, Gopal Chandru and Devikala, Sundaramurthy},
  title = {Development of an UPLC‐MS/MS approach to detect and quantify N‐nitroso mirabegron in mirabegron},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2024},
  doi = {10.1002/rcm.9911}
}
Kostenlos starten →