Test‐Retest Reliability, Measurement Error and Minimal Detectable Change of the Self‐Efficacy for Exercise‐Brazil in Individuals After Stroke
Physiotherapy Research International · 2026-07 · 31 (3)
DOI: 10.1002/pri.70257 ↗At a glance
Journal article in Physiotherapy Research International, published online on 2026-06-24. Written by Maria Tereza Mota Alvarenga and 2 co-authors. Institution: Department of Physiotherapy, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil. Major MEDLINE topics: Self Efficacy, Stroke, Stroke Rehabilitation, Exercise Therapy. 20 references. Funded by: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Topics: Schlaganfall
Abstract (original language)
Background and Purpose Identifying reliable methods to assess exercise self‐efficacy among individuals after stroke in Brazil is important. The purpose of the present study was to examine the test‐retest reliability, measurement error, and minimal detectable change of the Self‐Efficacy for Exercise‐Brazil in individuals after stroke.
Methods
The Self‐Efficacy for Exercise‐Brazil scale was administered twice to each participant by trained researchers, with an interval of 4–10 days between assessments. Test–retest reliability was evaluated using the ICC 3,1 . Measurement error was quantified by the standard error of measurement (SEM) and its percentage (SEM%), while the minimal detectable change (MDC) was calculated to identify the smallest score variation representing a true difference beyond measurement error.
Results
Fifty individuals after stroke were included, with a mean age of 61 years. The ICC 3,1 was 0.85 (95% CI = 0.75–0.91), the SEM was 1.08 points, the percentage of SEM was 20%, and the MDC was 2.99 points.
Discussion
The Self‐Efficacy for Exercise‐Brazil has adequate test–retest reliability after stroke. Moderate measurement error was observed, and changes of three points or more may reflect a true change.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Physiotherapy, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.
ORCID profiles: Maria Tereza Mota Alvarenga, Ruani Araújo Tenório, Aline Alvim Scianni
Funding
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Cite
APA
Alvarenga, M. T. M., Tenório, R. A., & Scianni, A. A. (2026). Test‐Retest Reliability, Measurement Error and Minimal Detectable Change of the Self‐Efficacy for Exercise‐Brazil in Individuals After Stroke. Physiotherapy Research International, 31(3). https://doi.org/10.1002/pri.70257
Vancouver
Alvarenga MTM, Tenório RA, Scianni AA. Test‐Retest Reliability, Measurement Error and Minimal Detectable Change of the Self‐Efficacy for Exercise‐Brazil in Individuals After Stroke. Physiotherapy Research International. 2026;31(3). doi:10.1002/pri.70257
BibTeX
@article{Alvarenga2026,
author = {Alvarenga, Maria Tereza Mota and Tenório, Ruani Araújo and Scianni, Aline Alvim},
title = {Test‐Retest Reliability, Measurement Error and Minimal Detectable Change of the Self‐Efficacy for Exercise‐Brazil in Individuals After Stroke},
journal = {Physiotherapy Research International},
year = {2026},
volume = {31},
number = {3},
doi = {10.1002/pri.70257}
}
EUVIMED