Test‐Retest Reliability, Measurement Error and Minimal Detectable Change of the Self‐Efficacy for Exercise‐Brazil in Individuals After Stroke
Physiotherapy Research International · 2026-07 · 31 (3)
DOI: 10.1002/pri.70257 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiotherapy Research International, online erschienen am 24.06.2026. Verfasst von Maria Tereza Mota Alvarenga und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil. Hauptthemen laut MEDLINE: Self Efficacy, Stroke, Stroke Rehabilitation, Exercise Therapy. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Themen: Schlaganfall
Abstract (Originalsprache)
Background and Purpose Identifying reliable methods to assess exercise self‐efficacy among individuals after stroke in Brazil is important. The purpose of the present study was to examine the test‐retest reliability, measurement error, and minimal detectable change of the Self‐Efficacy for Exercise‐Brazil in individuals after stroke.
Methods
The Self‐Efficacy for Exercise‐Brazil scale was administered twice to each participant by trained researchers, with an interval of 4–10 days between assessments. Test–retest reliability was evaluated using the ICC 3,1 . Measurement error was quantified by the standard error of measurement (SEM) and its percentage (SEM%), while the minimal detectable change (MDC) was calculated to identify the smallest score variation representing a true difference beyond measurement error.
Results
Fifty individuals after stroke were included, with a mean age of 61 years. The ICC 3,1 was 0.85 (95% CI = 0.75–0.91), the SEM was 1.08 points, the percentage of SEM was 20%, and the MDC was 2.99 points.
Discussion
The Self‐Efficacy for Exercise‐Brazil has adequate test–retest reliability after stroke. Moderate measurement error was observed, and changes of three points or more may reflect a true change.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physiotherapy, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.
ORCID-Profile: Maria Tereza Mota Alvarenga, Ruani Araújo Tenório, Aline Alvim Scianni
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Alvarenga, M. T. M., Tenório, R. A., & Scianni, A. A. (2026). Test‐Retest Reliability, Measurement Error and Minimal Detectable Change of the Self‐Efficacy for Exercise‐Brazil in Individuals After Stroke. Physiotherapy Research International, 31(3). https://doi.org/10.1002/pri.70257
Vancouver
Alvarenga MTM, Tenório RA, Scianni AA. Test‐Retest Reliability, Measurement Error and Minimal Detectable Change of the Self‐Efficacy for Exercise‐Brazil in Individuals After Stroke. Physiotherapy Research International. 2026;31(3). doi:10.1002/pri.70257
BibTeX
@article{Alvarenga2026,
author = {Alvarenga, Maria Tereza Mota and Tenório, Ruani Araújo and Scianni, Aline Alvim},
title = {Test‐Retest Reliability, Measurement Error and Minimal Detectable Change of the Self‐Efficacy for Exercise‐Brazil in Individuals After Stroke},
journal = {Physiotherapy Research International},
year = {2026},
volume = {31},
number = {3},
doi = {10.1002/pri.70257}
}
EUVIMED