Speech Quality Perception in Unilateral Cochlear Implant Users With Single‐Sided Deafness
Otolaryngology–Head and Neck Surgery · 2025
DOI: 10.1002/ohn.941 ↗Kurz gefasst
Fachartikel in der Zeitschrift Otolaryngology–Head and Neck Surgery, 2025. Verfasst von Scott Kelly und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons, New York-Presbyterian/Columbia Un…. Hauptthemen laut MEDLINE: Speech Perception, Cochlear Implants, Hearing Loss, Unilateral, Cochlear Implantation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
Objective
Cochlear implant (CI) users frequently complain about speech quality perception (SQP). In patients undergoing cochlear implantation for single‐sided deafness, there is concern that poor SQP from the implanted ear will negatively impact binaural (CI + normal hearing [NH]) SQP. In this study, we investigate if binaural SQP is measurably different than unimplanted NH alone. Study Design Cross‐sectional study.
Setting
Tertiary care center.
Methods
Fifteen unilateral CI users with NH in the contralateral ear completed the validated Columbia Speech Quality Instrument. This instrument consists of 9 audio clips rated across 14 specific speech qualities using a 10‐point visual analog scale. SQP was assessed in 3 conditions: CI only, NH only, and CI + NH.
Results
Median speech quality scores were worse in the CI only condition compared to the NH only (50.0 vs 72.6, P = .0003) and binaural (50.0 vs 71.0, P = .007) conditions. Median speech quality scores were not significantly different between the NH only and binaural conditions (72.6 vs 71, P = .8). Compared to NH, CI speech quality sounded less clear, less natural, and more mechanical.
Conclusion
Compared to NH, SQP is poorer with a CI alone. However, in contrast to expectation, there is no significant difference between NH and binaural SQP. This suggests poorer CI speech perception does not negatively impact binaural SQP in patients undergoing cochlear implantation for single‐sided deafness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons, New York-Presbyterian/Columbia University Irving Medical Center, New York, New York, USA.
- Department of Otorhinolaryngology, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, USA.
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University, Baltimore, Maryland, USA.
- Department of Mechanical Engineering, Columbia University, New York City, New York, USA.
ORCID-Profile: Scott Kelly, Isaac L Alter
Zitieren
APA
Kelly, S., Kuhlmey, M. E., Despotidis, M. A., Alter, I. L., Hwa, T. P., Chern, A., & Lalwani, A. K. (2025). Speech Quality Perception in Unilateral Cochlear Implant Users With Single‐Sided Deafness. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.941
Vancouver
Kelly S, Kuhlmey ME, Despotidis MA, Alter IL, Hwa TP, Chern A, et al. Speech Quality Perception in Unilateral Cochlear Implant Users With Single‐Sided Deafness. Otolaryngology–Head and Neck Surgery. 2025. doi:10.1002/ohn.941
BibTeX
@article{Kelly2025,
author = {Kelly, Scott and Kuhlmey, Megan E and Despotidis, Meghan A and Alter, Isaac L and Hwa, Tiffany P and Chern, Alexander and Lalwani, Anil K},
title = {Speech Quality Perception in Unilateral Cochlear Implant Users With Single‐Sided Deafness},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2025},
doi = {10.1002/ohn.941}
}
EUVIMED