EUVIMEDOpdag EUVIMED
Crossref

Speech Quality Perception in Unilateral Cochlear Implant Users With Single‐Sided Deafness

Scott Kelly iD, Megan E Kuhlmey, Meghan A Despotidis, Isaac L Alter iD, Tiffany P Hwa, Alexander Chern, Anil K Lalwani

Otolaryngology–Head and Neck Surgery · 2025

DOI: 10.1002/ohn.941 ↗

At a glance

Journal article in Otolaryngology–Head and Neck Surgery, 2025. Written by Scott Kelly and 6 co-authors. Institution: Department of Otolaryngology-Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons, New York-Presbyterian/Columbia Un…. Major MEDLINE topics: Speech Perception, Cochlear Implants, Hearing Loss, Unilateral, Cochlear Implantation. Cited 3 times so far (Crossref); 40 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objective

Cochlear implant (CI) users frequently complain about speech quality perception (SQP). In patients undergoing cochlear implantation for single‐sided deafness, there is concern that poor SQP from the implanted ear will negatively impact binaural (CI + normal hearing [NH]) SQP. In this study, we investigate if binaural SQP is measurably different than unimplanted NH alone. Study Design Cross‐sectional study.

Setting

Tertiary care center.

Methods

Fifteen unilateral CI users with NH in the contralateral ear completed the validated Columbia Speech Quality Instrument. This instrument consists of 9 audio clips rated across 14 specific speech qualities using a 10‐point visual analog scale. SQP was assessed in 3 conditions: CI only, NH only, and CI + NH.

Results

Median speech quality scores were worse in the CI only condition compared to the NH only (50.0 vs 72.6, P = .0003) and binaural (50.0 vs 71.0, P = .007) conditions. Median speech quality scores were not significantly different between the NH only and binaural conditions (72.6 vs 71, P = .8). Compared to NH, CI speech quality sounded less clear, less natural, and more mechanical.

Conclusion

Compared to NH, SQP is poorer with a CI alone. However, in contrast to expectation, there is no significant difference between NH and binaural SQP. This suggests poorer CI speech perception does not negatively impact binaural SQP in patients undergoing cochlear implantation for single‐sided deafness.

Subjects

MeSH terms (MEDLINE)

Speech PerceptionCochlear ImplantsHearing Loss, UnilateralCochlear ImplantationHumansMaleFemaleCross-Sectional StudiesMiddle AgedAgedAdultDeafness

Author keywords

CSQIcochlear implanthearing losssingle‐sided deafnessspeech quality perception

Authors and institutions

  • Department of Otolaryngology-Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons, New York-Presbyterian/Columbia University Irving Medical Center, New York, New York, USA.
  • Department of Otorhinolaryngology, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, USA.
  • Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University, Baltimore, Maryland, USA.
  • Department of Mechanical Engineering, Columbia University, New York City, New York, USA.

ORCID profiles: Scott Kelly, Isaac L Alter

Cite

APA

Kelly, S., Kuhlmey, M. E., Despotidis, M. A., Alter, I. L., Hwa, T. P., Chern, A., & Lalwani, A. K. (2025). Speech Quality Perception in Unilateral Cochlear Implant Users With Single‐Sided Deafness. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.941

Vancouver

Kelly S, Kuhlmey ME, Despotidis MA, Alter IL, Hwa TP, Chern A, et al. Speech Quality Perception in Unilateral Cochlear Implant Users With Single‐Sided Deafness. Otolaryngology–Head and Neck Surgery. 2025. doi:10.1002/ohn.941

BibTeX
@article{Kelly2025,
  author = {Kelly, Scott and Kuhlmey, Megan E and Despotidis, Meghan A and Alter, Isaac L and Hwa, Tiffany P and Chern, Alexander and Lalwani, Anil K},
  title = {Speech Quality Perception in Unilateral Cochlear Implant Users With Single‐Sided Deafness},
  journal = {Otolaryngology–Head and Neck Surgery},
  year = {2025},
  doi = {10.1002/ohn.941}
}
Start for free →