A Deep Learning Framework for Analysis of the Eustachian Tube and the Internal Carotid Artery
Otolaryngology–Head and Neck Surgery · 2024
DOI: 10.1002/ohn.789 ↗At a glance
Journal article in Otolaryngology–Head and Neck Surgery, 2024. Written by Ameen Amanian and 11 co-authors. Institution: Department of Biomedical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, Maryland, USA. Major MEDLINE topics: Eustachian Tube, Deep Learning, Carotid Artery, Internal, Tomography, X-Ray Computed. Cited 2 times so far (Crossref); 28 references. The full text is freely available in PubMed Central. Funded by: NIDCD NIH HHS.
Abstract (original language)
Objective
Obtaining automated, objective 3‐dimensional (3D) models of the Eustachian tube (ET) and the internal carotid artery (ICA) from computed tomography (CT) scans could provide useful navigational and diagnostic information for ET pathologies and interventions. We aim to develop a deep learning (DL) pipeline to automatically segment the ET and ICA and use these segmentations to compute distances between these structures. Study Design Retrospective cohort.
Setting
Tertiary referral center.
Methods
From a database of 30 CT scans, 60 ET and ICA pairs were manually segmented and used to train an nnU‐Net model, a DL segmentation framework. These segmentations were also used to develop a quantitative tool to capture the magnitude and location of the minimum distance point (MDP) between ET and ICA. Performance metrics for the nnU‐Net automated segmentations were calculated via the average Hausdorff distance (AHD) and dice similarity coefficient (DSC).
Results
The AHD for the ET and ICA were 0.922 and 0.246 mm, respectively. Similarly, the DSC values for the ET and ICA were 0.578 and 0.884. The mean MDP from ET to ICA in the cartilaginous region was 2.6 mm (0.7‐5.3 mm) and was located on average 1.9 mm caudal from the bony cartilaginous junction.
Conclusion
This study describes the first end‐to‐end DL pipeline for automated ET and ICA segmentation and analyzes distances between these structures. In addition to helping to ensure the safe selection of patients for ET dilation, this method can facilitate large‐scale studies exploring the relationship between ET pathologies and the 3D shape of the ET.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Biomedical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, Maryland, USA.
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Department of Otolaryngology-Head and Neck Surgery, University of British Colombia, Vancouver, British Colombia, Canada.
- Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati, Cincinnati, Ohio, USA.
- Department of Computer Science, Johns Hopkins University, Baltimore, Maryland, USA.
ORCID profiles: Ameen Amanian, Aseem Jain
Funding
- NIDCD NIH HHS
Cite
APA
Amanian, A., Jain, A., Xiao, Y., Kim, C., Ding, A. S., Sahu, M., Taylor, R., Unberath, M., Ward, B. K., Galaiya, D., Ishii, M., & Creighton, F. X. (2024). A Deep Learning Framework for Analysis of the Eustachian Tube and the Internal Carotid Artery. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.789
Vancouver
Amanian A, Jain A, Xiao Y, Kim C, Ding AS, Sahu M, et al. A Deep Learning Framework for Analysis of the Eustachian Tube and the Internal Carotid Artery. Otolaryngology–Head and Neck Surgery. 2024. doi:10.1002/ohn.789
BibTeX
@article{Amanian2024,
author = {Amanian, Ameen and Jain, Aseem and Xiao, Yuliang and Kim, Chanha and Ding, Andy S and Sahu, Manish and Taylor, Russell and Unberath, Mathias and Ward, Bryan K and Galaiya, Deepa and Ishii, Masaru and Creighton, Francis X},
title = {A Deep Learning Framework for Analysis of the Eustachian Tube and the Internal Carotid Artery},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2024},
doi = {10.1002/ohn.789}
}
EUVIMED