EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

3D Automated Segmentation of Bronchial Abnormalities on Ultrashort Echo Time MRI : A Quantitative MR Outcome in Cystic Fibrosis

Amel Imene Hadj Bouzid iD, Ilyes Benlala, Baudouin Denis de Senneville, Fabien Baldacci, Julie Macey, Wadie Benhassen, Pan Su, Stephanie Bui, Maeva Zysman, Aurelien Bustin iD, Patrick Berger, Gael Dournes iD

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.70196 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Amel Imene Hadj Bouzid und 11 weiteren Autor:innen. Beteiligte Einrichtung: Univ. Bordeaux, INSERM, CRCTB, UMR 1045, Bordeaux, France. Hauptthemen laut MEDLINE: Cystic Fibrosis, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Bronchi. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Nouvelle Aquitaine Region, Vaincre La Mucoviscidose.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cystic fibrosis (CF) monitoring relies on computed tomography (CT), but ultra‐short echo time MRI (UTE‐MRI) offers a radiation‐free alternative. However, its clinical adoption is hindered by the laborious and subjective manual analysis, which prevents standardized quantification of bronchial abnormalities.

Purpose

To develop a deep learning (DL) system for the segmentation of CF bronchial abnormalities on UTE‐MRI and assess clinical relevance in patients undergoing cystic fibrosis transmembrane conductance regulator (CFTR) modulator treatment. Study Type Retrospective. Population One‐hundred and sixty‐six CF patients were included (age = 23 ± 11, 48% male), comprising a training set ( n = 97), a test set ( n = 25), and an independent clinical validation cohort ( n = 44). Field Strength/Sequence 1.5T/UTE‐MRI 3D gradient‐echo Spiral Volume Interpolated Breath‐hold Examination (VIBE) sequence. Assessment The RiSeNet architecture was trained using paired UTE‐MRI and CT scans. Its technical performance was evaluated against expert‐refined segmentations and compared to state‐of‐the‐art segmentation models using topology‐aware metrics: Normalized Surface Dice (NSD) and CenterLine Dice (clDice). Clinical validation was performed by correlating automated measurements at baseline (M0) and 1‐year post‐CFTR modulator treatment (M12) with Bhalla scores and pulmonary function tests (FEV1%p). Statistical Tests Student's t ‐test, Mann–Whitney, Wilcoxon, and Chi‐square tests were used for group comparisons. The Spearman test was used to assess correlations. A p value < 0.05 was considered statistically significant.

Results

In the test group, RiSeNet achieved significantly superior performance versus state‐of‐the‐art with NSD scores of 0.84 for bronchiectasis, 0.90 for wall thickening, and 0.75 for mucus; and clDice scores of 0.69, 0.61, and 0.64, respectively. In the clinical validation group, significant correlations with Bhalla ( ρ = −0.92/−0.85) and FEV1%p ( ρ = −0.68/−0.67) were observed pre/post‐CFTR modulator. Post‐CFTR modulator, FEV1%p improved (69%–92%) with significant reductions in bronchiectasis (3.88–1.25), wall thickening (30.43–3.05), and mucus (53.30–11.80). Data Conclusion RiSeNet may enable semantic segmentation of CF abnormalities on radiation‐free UTE‐MRI. Evidence Level 3 Technical Efficacy 4

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cystic FibrosisMagnetic Resonance ImagingImaging, Three-DimensionalBronchiHumansMaleFemaleRetrospective StudiesAdultYoung AdultAdolescentDeep LearningTomography, X-Ray ComputedReproducibility of ResultsChildImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

Elexacaftor/Tezacaftor/IvacaftorUTE‐MRIcystic fibrosisdeep learningsegmentation

Autor:innen und Institutionen

  • Univ. Bordeaux, INSERM, CRCTB, UMR 1045, Bordeaux, France.
  • CHU de Bordeaux, Service D'imagerie Médicale, Bordeaux, France.
  • CHU de Bordeaux, Service de Pneumologie, Bordeaux, France.
  • Univ. Bordeaux, CNRS, Bordeaux INP, IMB, UMR 5251, Talence, France.
  • Univ. Bordeaux, CNRS, Bordeaux INP, LaBRI, UMR 5800, Talence, France.
  • Siemens Healthcare SAS, Courbevoie, France.

ORCID-Profile: Amel Imene Hadj Bouzid, Aurelien Bustin, Gael Dournes

Förderung

  • Nouvelle Aquitaine Region
  • Vaincre La Mucoviscidose

Zitieren

APA

Bouzid, A. I. H., Benlala, I., de Senneville, B. D., Baldacci, F., Macey, J., Benhassen, W., Su, P., Bui, S., Zysman, M., Bustin, A., Berger, P., & Dournes, G. (2025). 3D Automated Segmentation of Bronchial Abnormalities on Ultrashort Echo Time MRI : A Quantitative MR Outcome in Cystic Fibrosis. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70196

Vancouver

Bouzid AIH, Benlala I, de Senneville BD, Baldacci F, Macey J, Benhassen W, et al. 3D Automated Segmentation of Bronchial Abnormalities on Ultrashort Echo Time MRI : A Quantitative MR Outcome in Cystic Fibrosis. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.70196

BibTeX
@article{Bouzid2025,
  author = {Bouzid, Amel Imene Hadj and Benlala, Ilyes and de Senneville, Baudouin Denis and Baldacci, Fabien and Macey, Julie and Benhassen, Wadie and Su, Pan and Bui, Stephanie and Zysman, Maeva and Bustin, Aurelien and Berger, Patrick and Dournes, Gael},
  title = {3D Automated Segmentation of Bronchial Abnormalities on Ultrashort Echo Time MRI : A Quantitative MR Outcome in Cystic Fibrosis},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.70196}
}
Kostenlos starten →