Estimating Performance Using Tonotopic Measurements of Intracochlear Electrocochleography: Comparison of Lateral Wall and Perimodiolar Arrays
Otolaryngology–Head and Neck Surgery · 2026
DOI: 10.1002/ohn.70317 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Otolaryngology–Head and Neck Surgery, 2026. Verfasst von Jordan J Varghese und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Washington University School of Medicine, St. Louis, Missouri, USA. Hauptthemen laut MEDLINE: Audiometry, Evoked Response, Cochlear Implants, Cochlear Implantation. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
To assess intracochlear electrocochleography (ECochG) for estimating cochlear implant (CI) performance for lateral wall and perimodiolar electrode arrays. Study Design Prospective cohort study.
Setting
Tertiary referral center.
Methods
From December 2021 to June 2024, ECochG was measured intraoperatively using the Active Insertion Monitoring (AIM) system by Advanced Bionics. After insertion, multifrequency tone bursts were delivered via a sound tube from 250 Hz to 2 kHz at 95 to 105 dB HL with recordings at each internal electrode. Using spectral analysis, the maximal amplitude (MA) response electrode was identified by frequency and summed into a single value of total response (MA‐ECochG‐TR). Postoperative CI performance was routinely monitored.
Results
Of 57 participants with ECochG recordings, 43 completed 6‐month testing. Of these, 23 were perimodiolar (Mid‐Scala [MS]), and 20 were lateral wall (SlimJ [SJ]). MA‐ECochG‐TR had a moderately strong positive correlation to 6‐month consonant‐nucleus‐consonant (CNC) word scores for MS cases ( r = 0.73, 95% CI [0.46‐0.88], P < .001), but showed no significant correlation for SJ cases ( r = 0.04, 95% CI [−0.41 to 0.47], P = .87). For the 13 SJ recipients without electroacoustic stimulation (EAS), there was a moderate, non‐significant positive correlation between MA‐ECochG‐TR and 6‐month CNC ( r = 0.44, 95% CI [−0.14 to 0.80], P = .13).
Conclusion
MA‐ECochG‐TR independently estimates performance for perimodiolar arrays. Intracochlear ECochG is less predictive for lateral wall arrays; this may be due to confounding from EAS (though this was not statistically significant) or from signal degradation with a larger electrode‐modiolar distance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Washington University School of Medicine, St. Louis, Missouri, USA.
ORCID-Profile: Jordan J Varghese, Matthew A Shew, Amit Walia, Shannon M Lefler, Amanda J Ortmann, Nedim Durakovic, Cameron C Wick, Jacques A Herzog
Zitieren
APA
Varghese, J. J., Shew, M. A., Walia, A., Lefler, S. M., Ortmann, A. J., Durakovic, N., Wick, C. C., Herzog, J. A., & Buchman, C. A. (2026). Estimating Performance Using Tonotopic Measurements of Intracochlear Electrocochleography: Comparison of Lateral Wall and Perimodiolar Arrays. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.70317
Vancouver
Varghese JJ, Shew MA, Walia A, Lefler SM, Ortmann AJ, Durakovic N, et al. Estimating Performance Using Tonotopic Measurements of Intracochlear Electrocochleography: Comparison of Lateral Wall and Perimodiolar Arrays. Otolaryngology–Head and Neck Surgery. 2026. doi:10.1002/ohn.70317
BibTeX
@article{Varghese2026,
author = {Varghese, Jordan J and Shew, Matthew A and Walia, Amit and Lefler, Shannon M and Ortmann, Amanda J and Durakovic, Nedim and Wick, Cameron C and Herzog, Jacques A and Buchman, Craig A},
title = {Estimating Performance Using Tonotopic Measurements of Intracochlear Electrocochleography: Comparison of Lateral Wall and Perimodiolar Arrays},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2026},
doi = {10.1002/ohn.70317}
}
EUVIMED