A frequency peak at 3.1 kHz obtained from the spectral analysis of the cochlear implant electrocochleography noise
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0299911 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Javiera Herrada und 5 weiteren Autor:innen. Beteiligte Einrichtung: Servicio Otorrinolaringología, Hospital Clínico de la Universidad de Chile, Santiago, Chile. Hauptthemen laut MEDLINE: Cochlear Implantation, Cochlear Implants. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FONDECYT, ANID.
Abstract (Originalsprache)
Introduction
The functional evaluation of auditory-nerve activity in spontaneous conditions has remained elusive in humans. In animals, the frequency analysis of the round-window electrical noise recorded by means of electrocochleography yields a frequency peak at around 900 to 1000 Hz, which has been proposed to reflect auditory-nerve spontaneous activity. Here, we studied the spectral components of the electrical noise obtained from cochlear implant electrocochleography in humans.
Methods
We recruited adult cochlear implant recipients from the Clinical Hospital of the Universidad de Chile, between the years 2021 and 2022. We used the AIM System from Advanced Bionics ® to obtain single trial electrocochleography signals from the most apical electrode in cochlear implant users. We performed a protocol to study spontaneous activity and auditory responses to 0.5 and 2 kHz tones.
Results
Twenty subjects including 12 females, with a mean age of 57.9 ± 12.6 years (range between 36 and 78 years) were recruited. The electrical noise of the single trial cochlear implant electrocochleography signal yielded a reliable peak at 3.1 kHz in 55% of the cases (11 out of 20 subjects), while an oscillatory pattern that masked the spectrum was observed in seven cases. In the other two cases, the single-trial noise was not classifiable. Auditory stimulation at 0.5 kHz and 2.0 kHz did not change the amplitude of the 3.1 kHz frequency peak.
Conclusion
We found two main types of noise patterns in the frequency analysis of the single-trial noise from cochlear implant electrocochleography, including a peak at 3.1 kHz that might reflect auditory-nerve spontaneous activity, while the oscillatory pattern probably corresponds to an artifact.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Servicio Otorrinolaringología, Hospital Clínico de la Universidad de Chile, Santiago, Chile.
- Departamento de Neurociencia, Facultad de Medicina, Universidad de Chile, Santiago, Chile.
- Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago, Chile.
- Departamento de Fonoaudiología, Facultad de Medicina, Universidad de Chile, Santiago, Chile.
- Centro Avanzado de Ingeniería Eléctrica y Electrónica, AC3E, Universidad Técnica Federico Santa María, Valparaíso, Chile.
- Biomedical Neuroscience Institute, Facultad de Medicina, Universidad de Chile, Santiago, Chile.
ORCID-Profile: Vicente Medel, Constantino Dragicevic, Paul H Delano
Förderung
- FONDECYT
- ANID
Zitieren
APA
Herrada, J., Medel, V., Dragicevic, C., Maass, J. C., Stott, C. E., & Delano, P. H. (2024). A frequency peak at 3.1 kHz obtained from the spectral analysis of the cochlear implant electrocochleography noise. PLOS ONE. https://doi.org/10.1371/journal.pone.0299911
Vancouver
Herrada J, Medel V, Dragicevic C, Maass JC, Stott CE, Delano PH. A frequency peak at 3.1 kHz obtained from the spectral analysis of the cochlear implant electrocochleography noise. PLOS ONE. 2024. doi:10.1371/journal.pone.0299911
BibTeX
@article{Herrada2024,
author = {Herrada, Javiera and Medel, Vicente and Dragicevic, Constantino and Maass, Juan C and Stott, Carlos E and Delano, Paul H},
title = {A frequency peak at 3.1 kHz obtained from the spectral analysis of the cochlear implant electrocochleography noise},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0299911}
}
EUVIMED