EUVIMEDDescoperă EUVIMED
Open access · CC BY-NC-ND 4.0

Transcanal Excision of Exostoses: Large Series Comparing Bone Removal Methods

Jack Shohet iD, Drew Justeson, Allison Wilkins

Otolaryngology–Head and Neck Surgery · 2023

DOI: 10.1002/ohn.334 ↗

At a glance

Journal article in Otolaryngology–Head and Neck Surgery, 2023. Written by Jack Shohet and 2 co-authors. Institution: Shohet Ear Associates Medical Group Inc, Orange County, California, USA. Major MEDLINE topics: Tympanic Membrane Perforation, Exostoses. Cited 4 times so far (Crossref); 8 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Objective

External auditory exostosis (EAE) is a condition of progressive temporal bone growth into the external auditory canal most commonly from repeat cold water and wind exposure. Several tools have been utilized for EAE excision with varying implications for intra‐ and postoperative complications. However, comparisons of osteotome and microdrill are made difficult due to the few published cases and intervariability between surgeons. Furthermore, evidence is needed to analyze the safety of novel supplemental tools such as the piezoelectric bone‐cutting device. Study Design Retrospective chart review.

Setting

Medical clinic and surgery center.

Methods

A total of 413 subjects representing 472 ears met the inclusion criteria. Of which 159 ears were operated on using osteotome alone (OA), 271 using osteotome with a drill (OD), and 42 with osteotome with piezoelectric (OP). Charts were analyzed for the most reported intraoperative complications and postoperative symptoms and complications.

Results

There were no significant differences in the rate of tympanic membrane perforations nor in total intraoperative complications between OA, OD, or OP. The OD group contained the only nonperforation intraoperative event. OA had the lowest or near lowest incidence of all symptoms analyzed. OA showed a significantly lower incidence of tinnitus when compared to OD and OP.

Conclusion

We found that OA performed the best, though not statistically significant in most measures, with regard to mitigating rates of complications postsurgery. Our findings suggest OA provides lower risk intraoperatively and postoperatively for patients undergoing transcanal exostosis excision.

Subjects

MeSH terms (MEDLINE)

Tympanic Membrane PerforationExostosesHumansRetrospective StudiesEar CanalIntraoperative Complications

Author keywords

cutting drillexostosisosteotomepiezoelectrictranscanal approach

Authors and institutions

  • Shohet Ear Associates Medical Group Inc, Orange County, California, USA.
  • University of California, Irvine College of Medicine, Irvine, California, USA.
  • Virginia Commonwealth University College of Medicine, Richmond, Virginia, USA.

ORCID profiles: Jack Shohet

Cite

APA

Shohet, J., Justeson, D., & Wilkins, A. (2023). Transcanal Excision of Exostoses: Large Series Comparing Bone Removal Methods. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.334

Vancouver

Shohet J, Justeson D, Wilkins A. Transcanal Excision of Exostoses: Large Series Comparing Bone Removal Methods. Otolaryngology–Head and Neck Surgery. 2023. doi:10.1002/ohn.334